9.0 ELECTRICAL INFORMATION

WARNING: Do not use this fireplace if any part has been under water.
Immediately call a qualified service technician to inspect this appliance
and to replace any part of the control system and any gas control which
has been under water.
WARNING - Electrical Grounding Instructions: This appliance is
equipped with a three-prong (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the grounding
prong from this plug.

9.1 Electrical Specifications

This appliance, when installed, must be electrically grounded in
accordance with local codes, or in the absence of local codes, with
6V DC
TRANSFORMER
DEXEN MH3V
GAS VALVE
EV2
GREEN
(MAIN)
EV1
ORANGE
(PILOT)
Figure 9.1, Wiring Schematics
34 ELECTRICAL INFORMATION
RED BOOT
(FLAME SENSOR)
KOMFORT 8K
CONTROL MODULE
RED
DEX-TWH
RED
ROCKER SWITCH
GROUND
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.

9.2 Wiring Requirements

The wiring diagram for this appliance is shown in FIGURE 9.1 below.
The Komfort 8K system requires 120 VAC of electricity and/or
batteries to operate.
Using the battery backup will operate flame modulation of
the burner.
Optional fan component and light kit will not function on
battery backup power.
PILOT
BLACK BOOT
(IGNITER)
AUX 300
AUX 1
(LIGHT KIT)
BLACK
RED
ON/OFF
FAN KIT (optional)
AUX 3
(FAN)
MALE END
MALE END
LIGHT KIT
BATTERY PACK
6V DC
(with 1 amp fuse)
#SLA-60 R.8 March 2022