Maintenance; Firebox; Fan (Optional); Vent System - kozy heat SLAYTON-60 Installation And Operation Manual

Direct vent linear
Hide thumbs Also See for SLAYTON-60:
Table of Contents

Advertisement

13.0 MAINTENANCE

ATTENTION: Installation and repair should only be done by a qualified
service person. The appliance should be inspected before use and at
least annually by a professional service person. More frequent cleaning
might be required due to excessive lint from carpeting, bedding
material, et cetera. It is imperative that control compartments, burners,
and circulating air passageways of the appliance be kept clean. Use a
vacuum to clean all components.
WARNING: The appliance area must be kept clear and free from
combustible materials, gasoline and other flammable vapors and
liquids.

13.1 Firebox

Qualified Service Person
Performed by:
Annually
Frequency:
Action:
Vacuum and clean any
debris in the firebox that is not supposed
to be there.
Inspect and operate the bottom latch assembly. Verify the
assembly is free from obstruction to operate. The handles must
have spring tension but be

13.2 Fan (Optional)

CAUTION: Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Qualified Service Person
Performed by:
Every 6 months
Frequency:
Action:
Disconnect the fan from electrical current and vacuum.
The bearings are sealed and require no oiling.

13.3 Vent System

NOTE: If the vent-air intake system is disassembled for any reason,
reinstall per instructions provided with installation. Refer to Section
7.0 Venting on page 25.
Qualified Service Person
Performed by:
Annually
Frequency:
Action:
Examination of the vent system is required.
The flow of combustion and ventilation air must not be
obstructed.
#SLA-60 R.8 March 2022
able to move forward freely.
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces

13.4 Glass Assembly

CAUTION: Do not operate appliance with the glass assembly removed,
cracked, or broken. Use protective gloves to handle any broken or
damaged glass assembly components.
WARNING: Do not use substitute materials.
WARNING: Avoid striking or slamming glass assembly. Avoid abrasive
cleaner. DO NOT clean glass while it is hot.
IMPORTANT: Any safety screen, guard, or barrier removed for servicing
the appliance must be replaced prior to operating the appliance.
Homeowner
Performed by:
Annually
Frequency:
Action:
Prepare a work area large enough to accommodate the glass
assembly on a flat, stable surface.
Remove safety screen and glass frame assembly.
Clean glass window with a suitable fireplace glass cleaner using
a soft cloth. Abrasive cleaners must not be used. Be careful not to
scratch the glass when cleaning.
Reinstall glass assembly and safety screen. Do not operate
fireplace without safety screen.
Qualified Service Person
Performed by:
Annually
Frequency:
Action:
Clean glass window with a suitable fireplace glass cleaner using
a soft cloth. Abrasive cleaners must not be used. Be careful not to
scratch the glass when cleaning.
Inspect the glass for cracks, scratches, and nicks.
Verify the glass assembly is properly intact and not damaged.
Replace the glass and the assembly #701-011 as necessary.
Only Hussong Mfg. Co., Inc. will supply the replacement of glass
assembly as a complete unit.
MAINTENANCE 49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sla-60

Table of Contents