Electrical Information; Electrical Specifications; Wiring Requirements - kozy heat CHASKA 335S Installation And Operation Manual

Direct vent gas fireplace insert
Table of Contents

Advertisement

10.0 ELECTRICAL INFORMATION

WARNING: Do not use this fireplace if any part has been under water.
Immediately call a qualified service technician to inspect this appliance
and to replace any part of the control system and any gas control which
has been under water.
WARNING - Electrical Grounding Instructions: This appliance is
equipped with a three-prong (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the grounding
prong from this plug.

10.1 Electrical Specifications

WARNING: AN OPTIONAL COMPONENT CONNECTION IS FOR LOW
VOLTAGE BATTERY OR DIRECT CURRENT ONLY. DO NOT CONNECT TO
120 OR 240 VOLTS AC.
This appliance, when installed, must be electrically grounded in
accordance with local codes, or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.

10.2 Wiring Requirements

CAUTION: Do connect high voltage (115V) wire to the gas valve.
The millivolt gas valve system does not require 110-120 VAC
supply to operate.
If desired, a thermostat or a wall switch may be installed for main
burner operational control using low-voltage wires.
It is optional to disable rocker switch operating the main burner
by disconnecting the wires from the back of the gas valve.
If the rocker switch wires are not disconnected, the ON/OFF
rocker switch must be in the OFF position for proper operation
of optional controls. If the ON/OFF rocker switch is ON, the main
burner will operate until it is turned OFF by the rocker switch.
The thermostat/wall switch components will not turn the main
burner off if the main burner has been turned on by the rocker
switch.
If a the wall-mounted ON/OFF control or thermostat is to be
used, mount it in a convenient location on a wall near the
fireplace. Follow instructions included with assembly.
If an optional component is to be used, run low-voltage wires
from gas valve to the location of component.
#CSK-335S R.6 December 2018
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces