Electrical Information; Electrical Specifications; Wiring Requirements - kozy heat SP-41-L Installation And Operation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

9.0 Electrical Information

WARNING: Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to
inspect this appliance and to replace any part of the control system and any gas control which has been under water.
WARNING - Electrical Grounding Instructions: This appliance is equipped with a three-prong (grounding) plug for your
protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not
cut or
remove the grounding prong from this plug

9.1 Electrical Specifications

WARNING: An optional component connection for the SP34-MV is for low voltage battery or direct current only. Do not
connect to 120 or 240 volts. The optional fan kit is the only component on the MV system that connects to 120 volts.
This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

9.2 Wiring Requirements

9.2.1 SP-41-L Wiring Requirements
The system requires 120 VAC of electricity and/or batteries to operate.
Using the battery backup will operate flame modulation of the burner only.
9.2.2 SP-41-MV Wiring Requirements
The millivolt gas valve system does not require 120 VAC supply to operate. Do not connect 120 VAC to the gas valve.
If desired, a thermostat or a wall switch may be installed for main burner operation control using low voltage wires
(not included).
The ON/OFF rocker switch will override the thermostat / wall switch. If you choose to leave the rocker switch
wired up it must be placed in the OFF position to allow the thermostat / wall switch to operate correctly. If you
place the rocker switch in the ON position it will turn the fireplace on and override any command from the ther-
mostat / wall switch
It is optional to disable the ON/OFF rocker switch by disconnecting the wire from the back of the gas valve. If you
do this then the fireplace burner will only operate from the commands received from the thermostat / wall
switch.
If you choose to install the optional SP-028 fan kit then you will need 120 VAC at the appliance to power the fan kit.
Hussong Mfg. Co, Inc.
SP-41, PFS Report No. 19-561
49
Rev. 9 - November 2023