Electrical Information; Electrical Specifications; Wiring Requirements - kozy heat Nordik 41 DV Installation And Operation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

10.0 Electrical Information

WARNING: Do not use this fireplace if any part has been under
water. Immediately call a qualified service technician to inspect
this appliance and to replace any part of the control system and
any gas control which has been under water.
WARNING - Electrical Grounding Instructions: This appliance is
equipped with a three-prong (grounding) plug for your protec-
tion against shock hazard and should be plugged directly into a
properly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug

10.1 Electrical Specifications

This appliance, when installed, must be electrically grounded in
accordance with local codes, or in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, or the Canadian
Electrical Code, CSA C22.1.
Figure 10.1 - Electrical Diagram
Hussong Mfg. Co, Inc.
NDK-41-DV - PFS Report No. 22-838

10.2 Wiring Requirements

The system requires 120 VAC of electricity and/or batter-
ies to operate.
Using the battery backup will operate flame modulation
of the burner.
Fan and light components will not function on battery
back up power
50
Starting Serial Number: 23 N41DV00001 23
Rev. 1 - May 2023

Advertisement

Table of Contents
loading

Table of Contents