7.0 Electrical Information for Installation

7.1 Wiring to the Appliance

NOTE: Electrical wiring must be done in accordance with national, pro-
vincial, and/or local electrical codes.
WARNING: Disconnect electrical power from fireplace/power vent be-
fore performing any maintenance, repair, or electrical wiring.
NOTE: Electrical service of 120 VAC-60Hz must be supplied to the junc-
tion box of the fireplace in order for the power vent to operate correct-
ly. The current draw of this device is 0.85 amperes.
Ensure that the proper clearances are maintained for wiring and con-
duit. When installing the wiring, it must never run above the vent run
and it must be a minimum 1" (25mm) from all venting.
The battery back up will not run with power venting installed.
7.1.1 Prepare Power Vent Control Board
The S.I.T. Power Vent control board is sold separately and must be in-
stalled in place of the control module that was shipped with the fire-
place.

Use a flat blade screwdriver to pry the tabs of the top cover of the
control module to release.

Locate the JP1 jumper. It is a small plastic jumper that connects two
pins as shown in Figure 7.2.

Pull the plastic jumper straight up to expose the two individuals
pins underneath it. This changes the control module function from
a natural draft system to a power vent system. See Figure 7.3.

Reinstall control module top cover. Plug in all components previ-
ously unplugged.
7.1.2 Power Vent Control Board Installation

Remove the control board from housing (2) screws, and disconnect
all wires. Refer to the installation manual included with the fire-
place.

Install the Power Vent Control Board and reconnect the wiring as
previously removed.

Now we will connect the wire harness to the new control module.
Figure 7.1 - Remove IFC Cover
Figure 7.2 - Locate JP1 Jumper
Figure 7.3 - Remove JP1 Jumper