kozy heat SLA-42 Installation And Operation Manual

kozy heat SLA-42 Installation And Operation Manual

Direct vent linear fireplace

Advertisement

Quick Links

INSTALLATION AND OPERATION MANUAL
DIRECT VENT LINEAR FIREPLACE
IMPORTANT:
This installation manual is to be used in conjunction with SUPPLEMENTAL
INSTALLATION AND HOMEOWNER INFORMATION MANUAL. Read both manuals before installing
and operating appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located,
manufactured home (USA only) or mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If the information in these instructions is not followed exactly, a fire
or explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
◙ Do not try to light any appliance.
◙ Do not touch any electrical switch: do not use any phone in your building.
◙ Immediately call gas supplier from a neighbors phone. Follow the gas supplier
instructions
◙ If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service
agency or the gas supplier.
WARNING
HOT GLASS WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS.
www.kozyheat.com
English and French Installation Manuals
Available Through Your Local Dealer or
Visit Our Website at www.kozyheat.com
Report No. 216-S-36c-6.5
MARCH 2013
SLA-42-REV-04-SEPERATE

Advertisement

Table of Contents
loading

Summary of Contents for kozy heat SLA-42

  • Page 1 — Installation and service must be performed by a qualified installer, service agency or the gas supplier. WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. Report No. 216-S-36c-6.5 MARCH 2013 SLA-42-REV-04-SEPERATE www.kozyheat.com...
  • Page 2 Please retain this owner’s manual for future reference. CONGRATULATIONS! We welcome you as a new owner of a Kozy Heat gas fireplace. Kozy Heat products are designed with superior components and materials and assembled by trained craftsmen who take pride in their work. The burner and valve assembly are 100% test-fired and the complete fireplace is thoroughly inspected before packaging to ensure that you receive a quality product.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS VENTING (cont.) INTRODUCTION Introduction and Homeowner Reference Information Elbows CONTENTS Horizontal & Vertical Combination Venting Illustrations Table of Contents #800 Series Flex Vent Installation Instructions 20-21 SAFETY INFORMATION Termination Vent Cap Location Safety Information Vent Termination Clearances COMMONWEALTH OF MASSACHUSETTS INFORMATION LIGHT KIT Commonwealth of Massachusetts Information...
  • Page 4: Safety Information

    SAFETY INFORMATION This fireplace has been tested by OMNI-Test Laboratories, Portland, Oregon and complies with: ANSI Z21.88-2009/CSA 2.33-2009, “Standard for Vented Gas Fireplace Heaters.” CAN 2.14-M91 (R2009), “Gas-Fired for Use at High Altitudes.” CAN/CSA P.4.1-09, “Testing Method for Measuring Annual Efficiency”. This installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1 Installation and repair should be done only by a qualified service person.
  • Page 5 COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS NOTE The following requirements reference various Massachusetts and national codes not contained in this manual. For all sidewall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: INSTALLATION OF CARBON MONOXIDE DETECTORS...
  • Page 6: Specifications

    SPECIFICATIONS FIREPLACE DIMENSIONS FIREPLACE DESCRIPTION Height Width Back Width Depth Opening Glass Frame Top Stand-off Back to vent Width Height Height center DIMENSIONS INCHES 30-9/16 16-3/8 45-7/16 18-3/4 7-3/4 7-5/16 MILLIMETERS 1271 1271 1154 All stand-off brackets must be attached to fireplace. Do not remove. Top stand-off brackets are not load bearing. Non-combustible zone: Top stand-offs provide 7-3/4”...
  • Page 7: Additional Components Required

    Most TV manufacturers specify in their instructions that a TV should not be installed on, near, or above a heat source. Television location rests solely on the homeowner and Hussong Manufacturing will not be held liable for any adverse affects on a TV located near a Kozy Heat Fireplace that may be caused by heat.
  • Page 8: Fireplace Preparation

    FIREPLACE PREPARATION STAND-OFF / STAND-OFF HEAT SHIELD ASSEMBLY & INSTALLATION Top and back stand-off brackets must be formed and attached prior to positioning fireplace into framed opening. Top stand-offs provide 7-3/4” (197mm) minimum clearance to header. Use only non-combustible material in this area for entire WARNING width of fireplace.
  • Page 9: Nailing Flange Assembly & Installation

    FIREPLACE PREPARATION NAILING FLANGE ASSEMBLY & INSTALLATION Remove (4) nailing flanges from fireplace sides. With the 1/2” (13mm) long stand-offs on nailing flanges facing away from fireplace, align nailing flange with holes on outside corners of fireplace. Secure with screws (provided in components packet) through slots in nailing flanges. Bend perforation on nailing flange until parallel with fireplace face.
  • Page 10: Framing

    FRAMING WALL ENCLOSURE ROUGH OPENING Determine whether wall surface will be flush with fireplace face (wall and fireplace face will be covered with non-combustible material such as tile) or, framing will be flush with fireplace face, which results in a flat wall appearance. Header and top framing studs must be rotated.
  • Page 11: Vertical Terminations

    FRAMING Determine exact position of your fireplace, including hearth height, width, and depth, (if applicable). If possible, place fireplace in such a manner that vent termination will be placed between two studs, eliminating the need for additional framing. If masonry is to be used (optional), prepare necessary foundation for the masonry load. When masonry construction is being used, a lintel must be used over top of fireplace to support the added weight.
  • Page 12: Facing And Finishing

    FACING AND FINISHING This fireplace was designed to accommodate non-combustible facing material up to 1/2” (13mm) thick. Install non-combustible facing material up to facing flange surrounding the glass frame assembly. Do not apply any material beyond this point. The glass frame assembly must be removable.
  • Page 13: Typical Installation Options

    TYPICAL INSTALLATION OPTIONS Kozy Heat wall pass-thru (#800-WPT or #800-WPT2) must be used on all horizontal vent runs. Follow instructions on page 16 of this installation manual. IMPORTANT The horizontal heat shield included with this fireplace must be installed when incorporating minimum horizontal venting.
  • Page 14: Mantel Requirements

    MANTEL REQUIREMENTS Non-combustible zone: No combustible materials allowed on top of fireplace within shaded area for entire width and depth WARNING of fireplace with the exception of the header. Figure 13a GLASS FRAME DO NOT OPERATE THIS FIREPLACE WITH THE GLASS FRONT REMOVED, CRACKED OR BROKEN. WARNING REPLACEMENT OF THE GLASS SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON.
  • Page 15: Gas Line Connection

    GAS LINE CONNECTION GAS CONVERSION This fireplace is manufactured for use with Natural Gas. Follow instructions included with conversion kit if converting to LP gas. The conversion shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in ATTENTION accordance with the requirements of the ANSI Z223.1 installation code.
  • Page 16: Venting

    1 inch (25mm) 1 inch (25mm) ALL APPROVED VENTING Kozy Heat Wall Pass-thru, #800-WPT (4-1/2” (114mm) - 6-1/2” (165mm) wall thickness), IMPORTANT or #800-WPT2 (6-1/2” (165mm) -12-1/2” (318mm) wall thickness) must be used on all horizontal vent runs. The horizontal heat shield included with this fireplace must be installed when incorporating minimum horizontal venting. This applies to Nat.
  • Page 17 WARNING MAINTAIN ALL CLEARANCES AS STATED IN THIS INSTALLATION MANUAL. If using Kozy Heat series flexible vent system, remove inner ring on each wall pass-thru section with a tin snips. IMPORTANT This will provide adequate room for the flexible vent system.
  • Page 18 This applies to Nat. and LP minimum horizontal venting configurations. IMPORTANT Kozy Heat Wall Pass-thru, #800-WPT (4-1/2” (114mm) - 6-1/2” (165mm) wall thickness), or #800-WPT2 (6-1/2” (165mm) -12-1/2” (318mm) wall thickness) must be used on all horizontal vent runs. Flame height and appearance will vary depending upon venting configuration and type of fuel used.
  • Page 19: Vertical Vent System Clearances

    VENTING VERTICAL VENT SYSTEM CLEARANCES BOTTOM SIDES ALL APPROVED VERTICAL PIPE 1 inch (25mm) 1 inch (25mm) 1 inch (25mm) VERTICAL TERMINATIONS NOTE Horizontal Vent Heat Shield is not used on vertical venting configurations. MIN. / MAX. VERTICAL VENTING TERMINATION CAP APPLIES TO NAT AND LP INSTALLATIONS: MINIMUM: 2ft.
  • Page 20: Elbows

    The horizontal vent heat shield must be installed when using a 90-degree elbow to horizontally position the vent system. Kozy Heat Wall Pass-thru, #800-WPT (4-1/2” (114mm) - 6-1/2” (165mm) wall thickness) or, #800-WPT2 (6-1/2” (165mm) - 12-1/2” (318mm) wall thickness), must be used on all horizontal vent runs.
  • Page 21 IF TERMINATING AGAINST VINYL SIDING, A VINYL SIDING PROTECTOR, INCLUDED WITH #844-1 AND #845-1 DIRECT VENT KITS, MUST BE USED. FOLLOW INSTRUCTIONS INCLUDED. The Kozy Heat wall pass-thru, part #800-WPT or #800-WPT2, must be used on all horizontal vent applications regardless of IMPORTANT which vent system you are using.
  • Page 22 VENTING FLEXIBLE #800-1 SERIES cont. TERMINATION BOX SLOTS IN EXTERIOR WALL PLATE 5” FLEX PIPE COLLAR 5” PIPE ON FIREPLACE OR EXTENSION KIT 8” FLEX PIPE COLLAR 8” PIPE ON FIREPLACE OR EXTENSION KIT VINYL SIDING PROTECTOR (not shown) INTERIOR FIRESTOP Bend tabs up before attaching 8”...
  • Page 23: Termination Vent Cap Location

    TERMINATION VENT CAP LOCATION This gas appliance must not be connected to a chimney serving any other appliance. Terminations against vinyl siding must use a vinyl siding protector. Follow instructions included. DO NOT RECESS TERMINATION KIT INTO OUTSIDE BUILDING MATERIALS - i.e.: brick, stone, siding, etc. If necessary, extend framing so that termination kit will be exposed once building materials are installed.
  • Page 24: Vent Termination Clearances

    VENTING (Vertical Cap Requirements) VENT TERMINATION CLEARANCES Roof Pitch H (Min.) Ft. H (Min.) m Flat to 6/12 0.30 Over 6/12 to 7/12 1.25 0.38 Over 7/12 to 8/12 0.46 Over 8/12 to 9/12 0.61 Over 9/12 to 10/12 0.76 Over 10/12 to 11/12 3.25 0.99...
  • Page 25: Light Kit

    LIGHT KIT If converting to LP (propane) gas, do so now before installing light kit components. ATTENTION Follow instructions included with conversion kit (sold separately). CAUTION Disconnect all electric power from fireplace before performing this task. NOTE To avoid damage and prolong the life of halogen bulbs, never touch with bare hands. Always use a soft cloth when handling. Remove glass valance assembly.
  • Page 26: Control Board Removal

    CONTROL BOARD REMOVAL / INSTALLATION If burner and/or pilot have been burning, use appropriate protection to avoid burns or damage to personal property before CAUTION removing any components. DO NOT OPERATE THIS FIREPLACE WITHOUT SEALING GASKET (LOCATED UNDER CONTROL BOARD) IN PLACE. WARNING IF GASKETING IS DAMAGED, IT MUST BE REPLACED.
  • Page 27: Finalizing The Installation

    FINALIZING THE INSTALLATION FLAME APPEARANCE: Flame appearance is affected by several factors including altitude, venting configuration and fuel quality. Although the venturi setting has been factory set, adjustments may be necessary for optimal performance and visual aesthetics. When fireplace is first lit, the flames will be blue. Flames will gradually turn yellowish-orange during first 15 minutes of operation. If flames remain blue, or become dark orange with evidence of sooting (black tips), the burner tube venturi may need adjustment .
  • Page 28: Restrictor Troubleshooting / Installation After Termination Completion

    FINALIZING THE INSTALLATION RESTRICTOR USAGE: Turn fireplace on and allow to burn for 15 minutes. If flames indicate there is excessive draft (flickering, short flames), a restrictor may be necessary. If flames indicate insufficient draft (lifting or ghosting flames), a previously installed restrictor may need to be modified or removed. TO AVOID PROPERTY DAMAGE OR PERSONAL INJURY, ALLOW FIREPLACE AMPLE TIME TO COOL BEFORE MAKING ANY WARNING ADJUSTMENTS AND / OR INSTALLATIONS.
  • Page 29: Maintenance

    MAINTENANCE The appliance is required to be inspected at least once a year by a professional service person. The compartment below firebox must be cleaned at least once a year, more frequent cleaning may be required due to excessive lint from carpeting, bedding materials, or other fibrous materials.
  • Page 30 #970 HEAT DUCT KIT INSTRUCTIONS CAUTION Read and follow instructions carefully prior to and during installation of this optional heat duct kit INSTALLATION OF THIS DUCT KIT & ELECTRICAL WIRING MUST BE PERFORMED BY A QUALIFIED SERVICE PERSON AND IN ACCORDANCE WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL ELECTRICAL CODE, ANSI/ WARNING NFPA 70, OR THE CANADIAN ELECTRICAL CODE, CSA C22.1.
  • Page 31 #970 HEAT DUCT KIT INSTRUCTIONS PREPARE THE FIREPLACE Remove one 6" diameter knock-out located at top of fireplace. If both heat ducts will be used, remove both knock-outs. Bend 3 tabs up & out far enough to allow duct collar & duct pipe installation. For each 6”...
  • Page 32 #970 HEAT DUCT KIT INSTRUCTIONS INSTALL REGISTER MOUNTING FRAME, JUNCTION BOX, RUN WIRING Register mounting frame and fan housing are designed to fit between 2” x 4” stud walls, 16” (406mm) on center. Additional framing is required if larger opening exists. Fan motor on heat duct kit may be on opposite side of fan shown in photos.
  • Page 33 #970 HEAT DUCT KIT INSTRUCTIONS RUN DUCT PIPE Run duct pipe to register location. If oval pipe will be used in conjunction with 6” (152mm) round duct pipe, shape round duct pipe to fit outside oval duct pipe. Secure with screws provided. If oval duct pipe has not been used, shape 6”...
  • Page 34: Warranty

    Failure to do so may result in delayed warranty coverage and submission of proof of purchase will be required. Hussong Manufacturing Co., Inc. warranties to the original purchaser of this Kozy Heat Fireplace, that it is free of defects in materials and workmanship at the time of manufacture.
  • Page 35: Warranty

    LIFETIME WARRANTY IS EXTENDED AS FOLLOWS: Hussong Manufacturing Co., Inc. warranties to the original purchaser that the firebox, heat exchanger, fiber logs, burner tube and glass panel of this Kozy Heat Fireplace will not be defective in materia l or workmanship under normal use and service for as long as you own this product.
  • Page 36 Supplemental Installation and Homeowner I n f o r m a t i o n M a n u a l f o r S L A Y T O N 4 2 : DIRECT VENT GAS LINEAR FIREPLACE English and French Installation Manuals Available Through Your Local Dealer or Visit Our Website at www.kozyheat.com Les manuels d’installation en anglais et en français sont disponibles chez votre détaillant local ou en visitant notre site Web : www.kozyheat.com IMPORTANT: This supplemental installation and homeowner manual is to be used in...
  • Page 37 TABLE OF CONTENTS SAFETY INFORMATION Safety Information SPECIFICATIONS Components List Gas Pressure Requirements / BTU’s OPTIONAL FAN KIT INSTALLATION Optional Fan Kit Installation WIRING SCHEMATICS Wiring Schematics OPERATING INSTRUCTIONS Control System Components System Operations 7-10 Lighting and Shutdown 11-12 Pressure Testing TROUBLESHOOTING Troubleshooting 14-15...
  • Page 38: Safety Information

    SAFETY INFORMATION This fireplace has been tested by OMNI-Test Laboratories, Portland, Oregon and complies with: ANSI Z21.88-2009/CSA 2.33-2009, “Standard for Vented Gas Fireplace Heaters” CAN/CGA 2.17-M91 (R2009), “Gas-Fired Appliances for Use at High Altitudes” CAN/CSA P.4.1-09, “Testing Method for Measuring Annual Efficiency” This installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1 The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, wth the National...
  • Page 39: Specifications

    SPECIFICATIONS COMPONENTS LIST PART NUMBER DESCRIPTION SL42-150 Control Board Assembly SL42-135 Burner Assembly SL42-BLK Light Kit SL42-057T Glass Frame Assembly 700-408 Remote Control 600-002 Double Receptacle Assembly 942-085 5” Restrictor Plate SL42-HHS Horizontal Vent Heat Shield NATURAL GAS LP GAS 5”...
  • Page 40: Optional Fan Kit Installation

    OPTIONAL FAN KIT INSTALLATION INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER MAKE SURE HOUSEHOLD BREAKER IS SHUT OFF PRIOR TO WORKING ON ANY ELECTRICAL LINES. WARNING THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE.
  • Page 41: Wiring Schematics

    WIRING SCHEMATICS THIS SYSTEM REQUIRES ELECTRICITY (120V) AND / OR BATTERIES TO OPERATE. IMPORTANT USING BATTERY BACK UP WILL OPERATE BURNER ONLY. FAN AND LIGHT COMPONENTS WILL NOT FUNCTION ON BATTERY BACK-UP POWER. Figure 5a...
  • Page 42: Control System Components

    CONTROL SYSTEM COMPONENTS REMOTE CONTROL Blue back lit LCD display ON /OFF Key Thermostat Key UP / DOWN Arrow Key Key Lock Mode Key Low Battery Alarm Transmission Thermostat OFF/ON/SMART Room Temperature CPI Mode Set Point Temperature/Level/State Flame ON Figure 6a Lights (not available in all fireplace models) GAS VALVE Stepper motor...
  • Page 43: System Operations

    SYSTEM OPERATION INITIALIZING THE SYSTEM FOR THE FIRST TIME Set ON/OFF rocker switch to OFF position. Install 4 AA batteries (included in components packet) into battery backup holder. LEDs Connect IFC Control Module to AC power supply. Install 3 AAA batteries (included in components packet) into remote control battery bay (located on base of remote control).
  • Page 44 SYSTEM OPERATION ROOM THERMOSTAT (Remote Control Operation) The remote control can operate as a room thermostat. The thermostat can be set to desired temperature to control a rooms comfort level. To activate this function, press the Thermostat Key. The LCD display will change to show the room thermostat is ON and set temperature is now displayed.
  • Page 45 SYSTEM OPERATION LOW BATTERY DETECTION REMOTE CONTROL: Remote control battery lifespan depends on various factors including battery quality, number of ignitions, changes to room thermostat set point, etc. When remote control batteries are low, a Battery Icon will appear on the LCD display before all battery power is lost.
  • Page 46 SYSTEM OPERATION S .I .T. PRO FL A ME 2 I FC I G NI T I O N AND RE S E T I NFO RMAT I O N IGNITION SEQUENCE Starting from OFF, press remote control ON button. Approximately (4) seconds after ON/OFF button is pushed, the IFC control module will start the spark.
  • Page 47: Lighting And Shutdown

    LIGHTING AND SHUTDOWN FOR YOUR SAFETY - READ BEFORE OPERATING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT, WARNING CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. 1. This appliance is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand. 2.
  • Page 48 LIGHTING AND SHUTDOWN (cont.) OPERATING INSTRUCTIONS Read safety information on previous page and front STOP! c o v e r o f t h i s m a n u a l b e f o r e c o n t i n u i n g . Turn off all electric power to the appliance.
  • Page 49: Pressure Testing

    PRESSURE TESTING Pressure check taps for manifold (outgoing) and inlet (incoming) pressure have been incorporated into the valve. The pressure IMPORTANT tap marked OUT measures outgoing pressure and the pressure tap marked IN measures incoming pressure. Follow instructions below for proper testing procedures. Refer to page 17 for proper NAT and LP manifold pressures. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
  • Page 50: Troubleshooting

    TROUBLESHOOTING ATTENTION TROUBLESHOOTING MUST BE PERFORMED BY A QUALIFIED TECHNICIAN. Before proceeding with the steps in the following troubleshooting guide, verify the power supply is present and receiver batteries and/or battery pack are fresh and installed with correct polarity. Make sure all connections between wire harnesses and system components are proper and positive. Make sure communication link between remote control and IFC control module is established.
  • Page 51 TROUBLESHOOTING PILOT AND BURNER EXTINGUISH WHILE IN OPERATION No LP in tank. Check and refill if necessary. Glass frame assembly not installed correctly. Refer to corresponding instructions in this manual. Improper vent cap installation. Adjust if necessary. Vent cap blockage. Remove debris if necessary. Improper pitch on horizontal vent.
  • Page 52: Conversion Kit Instructions

    CONVERSION KIT INSTRUCTIONS #NCK-SL42-SP NAT GAS CONVERSION KIT / #LCK-SL42-SP LP GAS CONVERSION KIT This conversion kit shall be installed by a qualified service agency in accordance with the manufacturers instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or productions of carbon monoxide may result, causing property damage, personal injury or loss of life.
  • Page 53 CONVERSION KIT INSTRUCTIONS CONVERT THE GAS CONTROL VALVE: Follow stepper motor pressure regulator instruction sheet included with conversion kit to convert gas valve. ( L P o r N A T m a r k e d o n s t e p p e r m o t o r p r e s s u r e regulator).
  • Page 54: Finalizing The Installation

    FINALIZING THE INSTALLATION FLAME APPEARANCE: Flame appearance is affected by several factors including altitude, venting configuration and fuel quality. Although the venturi setting has been factory set, adjustments may be necessary for optimal performance and visual aesthetics. When fireplace is first lit, the flames will be blue. Flames will gradually turn yellowish-orange during first 15 minutes of operation. If flames remain blue, or become dark orange with evidence of sooting (black tips), the burner tube venturi may need adjustment.
  • Page 55: Maintenance

    MAINTENANCE MAINTENANCE The appliance is required to be inspected at least once a year by a professional service person. The compartment below firebox must be cleaned at least once a year, more frequent cleaning may be required due to excessive lint from carpeting, bedding materials, or other fibrous materials.
  • Page 56 1-1/8” Glass gasket w/ adhesive SL42-057T Valance with 17-5/8” (448mm) x 44-5/16” (1141mm) glass LIGHT KIT SL42-BLK Light Kit (bottom) 600-676 35W 130V Halogen Bulb Hussong Manufacturing Co., Inc. P.O. Box 577 204 Industrial Park Drive Lakefield, MN 56150-0577 www.kozyheat.com SLA-42...