10.6 Komfort 8K Control System
Ignition Sequence
The Komfort 8K control module will attempt (1) time for ignition, for
approximately 60 seconds.
If there is no flame ignition (rectification) within the (60) second
time frame, the Komfort 8K system will go into a lockout. The control
module will display an error code (see section 10.7), followed by a
blinking red/green LED, indicating a system lockout.
10.6.1 Reset Control Module after Lockout
10.6.1.1 Disconnect Power Supply
Disconnect the power supply to the control module. After
approximately (5) second, reconnect power supply.
10.6.1.2 ON/OFF/REMOTE Switch
Turn the ON/OFF/REMOTE switch on the control module to OFF.
Wait approximately (5) seconds, and turn the ON/OFF/REMOTE
switch to REMOTE. The control module will illuminate a green
LED (2) times and emit a beep.
Turn the ON/OFF/REMOTE switch on the control module to OFF.
Wait approximately (5) seconds, and turn the ON/OFF/REMOTE
switch to ON. The control module will illuminate a green LED (2)
times and emit a beep. The ignition sequence will start again.

10.7 Additional Diagnostic Information

Diagnostic codes are outlined below and should be used as an
additional troubleshooting tool.
Red LED will blink (1) time, then a red/green LED blink (lockout)
Error caused by fuel-type selector switch is in incorrect position
or fuel-type selector switch is damaged. Verify selector is in
correct position. If condition persists, replace the control module.
Red LED will blink (2) times, then a red/green LED blink (lockout)
Error caused by Insufficient voltage from ignition coil to pilot
flame igniter. Clear the lockout (see section 10.6.1 above)
and attempt ignition. If condition persists, replace the control
module.
Red LED will blink (3) times, then a red/green LED blink (lockout)
Error caused by inadequate gas supply. Verify proper inlet
pressure to the gas line.
Error caused by detection of false flame or short in sensor lead.
Verify that pilot leads are correctly terminated to the control
module, and that no shorted wires exist.
Error caused by sense and/or igniter lead disconnected. Verify
that the pilot sensor rod, igniter rod, and hood are clean.