Vent Heat Shield Assembly Installation - kozy heat SLAYTON-60 Installation And Operation Manual

Direct vent linear
Hide thumbs Also See for SLAYTON-60:
Table of Contents

Advertisement

7.8 Vent Heat Shield Assembly Installation

IMPORTANT: The vertical vent heat shield MUST be installed for every
type of venting application. The horizontal vent heat shield must be
installed when incorporating minimum horizontal venting.
NOTE: There are (6) screw holes located in front of the flue outlet to
offset the vent heat shield assembly in front of the vent pipe. Align the
heat shield as necessary for your venting installation.
7.8.1 Vertical Vent Heat Shield Installation
1.
Position the vertical vent heat shield in front of the vent pipe,
with the flanges facing towards the fireplace face as necessary
for the type of installation.
2.
Align the (2) slots on the vertical heat shield flanges with
corresponding screw holes located in front of the flue outlet on
the top of the fireplace.
3.
Secure the vertical vent heat shield to the fireplace with (2)
attachment screws (provided in the components package).
7.8.2 Minimum Horizontal Venting
1.
Bend perforation on the (3) hand-tabs down on the horizontal
vent heat shield.
2.
Locate (3) screw holes at the top of the vertical vent heat
shield. For Propane vent installations, attach the 6 in (152mm)
attachment piece to the vertical vent heat shield.
3.
Align the (3) slots on horizontal vent heat shield tabs to the
corresponding (3) screws holes on the vertical vent heat shield
necessary for your installation.
4.
Attach the horizontal vent heat shield with screws (provided)
through the screw holes on the vertical vent heat shield. The 1 in
(25 mm) vent stand-off tab will rest on top of the vent pipe.
Figure 7.6, Installed Vent Heat Shield Assembly
30 VENTING
Figure 7.7, Installed Horizontal Vent Heat Shield
PROPANE SCREW LOCATION
NATURAL GAS SCREW LOCATION
Figure 7.8, Vent Heat Shield Assembly
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
VENT STAND-OFF TAB
HORIZONTAL VENT
HEAT SHIELD
6" (152mm) PROPANE
ATTACHMENT PIECE
VERTICAL VENT HEAT SHIELD
#SLA-60 R.8 March 2022

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sla-60