kozy heat SLAYTON 36 Installation And Operation Manual

kozy heat SLAYTON 36 Installation And Operation Manual

Direct vent
Table of Contents

Advertisement

Quick Links

S L AY TO N 3 6
INSTALLATION AND OPERATION MANUAL
Model #SLA-36
Direct Vent Gas Fireplace
English and French installation manuals are available through your local
dealer. Visit our website www.kozyheat.com.
Les manuels d'installation en français et en anglais sont disponibles chez
votre détaillant local. Visitez www.kozyheat.com.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property
damage.
ͷ Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
ͷ WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
ͷ Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Hussong Mfg. Co., Inc.
SLA-36 Report No: 19-504
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an
aftermarket,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
DANGER
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed for the protection
of children and other at-risk individuals.
permanently
located,
HOT GLASS WILL
CAUSE BURNS
DO NOT TOUCH GLASS
UNTIL COOLED
NEVER ALLOW CHILDREN
TO TOUCH GLASS
Rev. 12, March 2022
Starting Serial Number: 22 076200 13

Advertisement

Table of Contents
loading

Summary of Contents for kozy heat SLAYTON 36

  • Page 1 S L AY TO N 3 6 INSTALLATION AND OPERATION MANUAL Model #SLA-36 Direct Vent Gas Fireplace English and French installation manuals are available through your local dealer. Visit our website www.kozyheat.com. Les manuels d’installation en français et en anglais sont disponibles chez votre détaillant local.
  • Page 3: Homeowner Reference Information

    Read this manual before installation or operating this appliance. Please retain this owner’s manual for future reference. CONG R ATU L ATI ONS ! We welcome you as a new owner of a Kozy Heat gas fireplace. Kozy Heat products are designed with superior components and materials, and assembled by trained craftsmen who take pride in their work.
  • Page 5: Table Of Contents

    7.1 Approved Vent Systems ................29 7.2 Venting Requirements ................29 7.3 Vent Restriction ................... 30 7.4 Vent Installation ..................31 7.5 #800-1 Series Direct Vent Termination Kit(s) ........39 #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 7: Introduction

    Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. #SLA-36 #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022 R.12 March 2022...
  • Page 8: Specifications

    • The AC power supply to this appliance must be hot at all times and shall not have a switch installed in it. #SLA-36 #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022 R.12 March 2022...
  • Page 9: Appliance Dimensions

    ⁄ ⁄ ” ⁄ ” ” HOLE (107mm) (155mm) (148mm) ⁄ ” (200mm) ⁄ ⁄ ” ” ¾ ” (1108mm) (130mm) (121mm) ¾ ” (1238mm) FIGURE 2.1 SLA-36 Dimensions #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 10: Safety Barrier Dimensions

    ⁄ ⁄ ” ” (79mm) (81mm) ¾ ⁄ ” ” (1162mm) (1151mm) ⁄ ” SL36-RSF (503mm) ⁄ ” (24mm) ⁄ ” FINISHING (1040mm) EDGE FIGURE 2.2 Safety Barrier Dimensions #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 11: Framing

    • This fireplace may be installed in a bedroom. • Please be aware of the large amount of heat this fireplace will produce when determining a location. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 12: Stand-Off Assembly And Installation

    DO NOT FORM UNTIL SECURED. FORMED STAND OFF BACK STAND-OFFS BRACKETS AS SHIPPED BEND AT PERFORATIONS TOP STAND-OFF BRACKETS INSTALLED BACK STAND-OFF BRACKETS INSTALLED FIGURE 3.1 Stand-off Assembly and Installation #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 13: Nailing Flange Assembly And Installation

    NAILING FLANGE INSTALLED NAILING FLANGE INSTALLED TOP VIEW FRONT VIEW FRAMING STUD ½ ” (64mm) STAND-OFF FLANGE NAILING FLANGE CLEARANCE FRAMING STUD NAILING FLANGE FIGURE 3.2 Nailing Flange Installation #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 14: Clearances To Combustibles

    ⁄ ” (1807mm) (1807mm) TYPICAL CORNER INSTALLATION ⁄ ” (816mm) ⁄ ” (1398mm) ⁄ ” ⁄ ” (2797mm) (1807mm) ⁄ ” 4” (1977mm) (102mm) FIGURE 3.3 Typical Install Options #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 15: Rough Framing

    If replace face is to be ush with the wall surface, subtract 1/2” (13mm) (typical non-combustible nish material) from this dimension. If other material is to be used, adjust accordingly. FIGURE 3.4 Rough-in Framing #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 16 IMPORTANT: Horizontal vent sections require 1/4” (6mm) rise for every 12” (305mm) of travel. Kozy Heat’s #800-WPT3, or wall thimble products that comply with the required 1” (25mm) clearance to combustibles must be installed for all horizontal vent (rigid or flexible) runs that pass through interior or exterior walls.
  • Page 17 (905mm) REQUIRED WALL PASS THROUGH FRAMING FOR 1” 25MM CLEARANCE SHOWN WITH #800 WPT3 11” (279mm) ” ¾ (273mm) ⁄ ” (138mm) FIGURE 3.5 Rough-in Minimum Horizontal Termination Framing #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 18: Outdoor Covered Fireplace Installation

    EXAMPLE: If roo ine (B) is 10’ above the base of replace, the overhang (A) must be 5’ or greater. The width of the overhang to EACH side of the replace (C) must be 5’ or greater. FIGURE 3.6 Outdoor Covered Fireplace Install - 1 #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 19 MEMBRANE IS NOT TO BE INTERRUPTED BY FIREPLACE INSTALLATION MINIMUM WEATHERPROOF OVERHANG IN FRONT AND SIDES OUTSIDE INSIDE FREE STANDING STRUCTURE (WEATHERPROOF ENCLOSURE) FIGURE 3.7 Outdoor Covered Installation - 2 #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 20: Facing And Finishing

    • For a painted surface, use a high quality acrylic latex primer and finish coat. Avoid flat or light-colored paints to prevent discoloring. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 21 ” (848mm) ¼ ” (641mm) ¼ ” ¼ (489mm) ” (1581mm) ¼ ” (362mm) 1/2” (25mm) Non-Combustible Material ONLY FINISHING EDGE 40” (1016mm) COMBUSTIBLE FLOORING FIGURE 4.1 Mantel Clearances #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 22 ¼ ” (274mm) (1581mm) ⁄ ” (930mm) 18” (457mm) ¼ ¾ ¾ ” ” ” (997mm) (121mm) (121mm) ⁄ ” (200mm) ¾ ” (1238mm) FIGURE 4.2 Framed Opening Dimensions #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 23 NO SCREWS ABOVE FRAMING (BOTTOM ¾” [19mm]) ⁄ ¾ ” ” (219mm) (19mm) NON-COMBUSTIBLE COMBUSTIBLE MATERIAL COMBUSTIBLE MATERIAL ALLOWED MATERIAL ONLY ALLOWED NO SCREWS FIGURE 4.3 Minimum Non-Combustible Material Dimensions #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 24: Safety Barrier Installation

    Lower the screen front until the notched tabs are firmly in position, verifying the depth accommodates finish material. • To remove safety screen: lift the screen up and out of slots. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 25: Optional Trim Kit Assembly #Sl36-Ftk

    Align the top and bottom trim panels with the pre-drilled holes on the fireplace face. Position the flange on the trim panel as pictured below. Secure with screws included in components packet. FIGURE 4.4 Trim Kit Installation #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 26: Gas Line Connection

    Table 5.1, Inlet Gas Supply Pressures Fuel Minimum Pressure Maximum Pressure Natural Gas 5” WC (1.25 kPa) 10” WC (2.49 kPa) Propane 12” WC (2.99 kPa) 13” WC (3.24 kPa) #SLA-36 #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022 R.12 March 2022...
  • Page 27: Termination Locations

    Over 12/12 to 14/12 1.52 Over 14/12 to 16/12 1.83 Over 16/12 to 18/12 2.13 Over 18/12 to 20/12 2.27 Over 20/12 to 21/12 2.44 FIGURE 6.1 Vertical Vent Cap Clearance #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 28: Minimum Vent Termination Clearances

    VINYL SOFFIT, VINYL CEILING, AND VINYL OVERHANG DISCLAIMER: Clearances to heat resistant material (i.e. wood, metal). This does not include vinyl. Hussong Manufacturing Co., Inc. will not be held responsible for heat damage caused from terminating under vinyl overhangs, vinyl ceilings, or vinyl ventilated/unventi- lated soffits. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 29: Venting

    This appliance is equipped for use with a 5” (127mm) exhaust by 8” (203mm) air intake co-axial vent pipe system. This appliance is approved for use for Kozy Heat 800 Series Flexible Vent Kit (sold separately). Refer to section 7.5, #800-1 SERIES DIRECT VENT TERMINATION KIT(S) on page 39.
  • Page 30: Vent Restriction

    SLIDE RESTRICTOR INTO EXHAUST PIPE ON TOP OF FIREPLACE WITH TABS FACING TOWARDS YOU PRIOR TO ATTACHING VENTING TERMINATION ACCESS PANEL (2 SCREWS) FIGURE 7.1 Restrictor Assembly and Installation #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 31: Vent Installation

    NOTE: A restrictor plate is recommended for 30’ (9.14m) to 50’ (15.2m) of vertical venting if no elbows are used. (i) Minimum/ Maximum Vertical Venting: 2’ (610mm) minimum vertical length / 50’ (15.24m) maximum vertical length + termination cap #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 32 (i) Minimum Horizontal Terminations: 90° horizontal elbow + 9” (229mm) minimum horizontal run + termination cap (i) Maximum Horizontal Terminations: 90° horizontal elbow + 4’ (1219mm) maximum horizontal run + termination cap #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 33 20’ (6m) maximum vertical rise + 20’ (6m) maximum horizontal run = 40’ (12.2m) of total length • Maximum of (5) 90° elbows. FIGURE 7.2 Natural Gas 5” x 8” Combination Venting #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 34 (ii) Minimum Vertical Rise / Maximum Horizontal Termination: 6” + 9” (152mm + 229mm) vertical vent pipe + 90° horizontal elbow + 4’ (1219mm) maximum horizontal run + termination cap #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 35 = 40’ (12.2m) of total length • (2) 45° degree elbows may be used in place of (1) 90° elbow. • Maximum of (5) 90° elbows. FIGURE 7.3 Propane 5” x 8” Combination Venting #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 36 (i) Minimum/ Maximum Vertical Venting: 4” x 6-5/8” vent reducer + 2’ (610mm) minimum vertical length / 50’ (15.24m) maximum vertical length + termination cap #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 37 (i) Minimum Vertical Rise / Maximum Horizontal Termination: 4” x 6-5/8” vent reducer + 12” (305mm) minimum vertical rise + 4” x 6-5/8” 90° horizontal elbow + 3’ (914mm) maximum horizontal run+ termination cap #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 38 (6.1m) max 4” x 6-5/8” horizontal length = 40’ ( 2.2m) • (2) 45° degree elbows may be used in place of (1) 90° elbow. FIGURE 7.4 Natural Gas and Propane 4” x 6-5/8” Combination Venting #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 39: 800-1 Series Direct Vent Termination Kit(S)

    Apply a liberal bead of exterior sealant around outer edge of termination box (A), placing assembly through the wall-pass through in exterior wall. Place screws through the four holes (B), securing it in place. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 40: Fireplace Set Up

    Reinstall valve access cover, using screws previously removed. Reinstall safety barrier. HINGE SCREW SECURING VALVE TO ACCESS COVER (1 EACH SIDE) HANDLE LOCATION FIGURE 8.1 Glass Frame Assembly Removal and Installation #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 41: Glass Media

    PROPANE INSTALLATIONS: Install 7 lbs. (3.175 kg) of reflective glass onto the burner assembly and pilot shield. Do not block pilot assembly. Save any unused media for later use. FIGURE 8.2 Pilot Assembly Area #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 42: Control Board Removal And Installation

    Turn the manual valve counterclockwise to the ON position. 10. Reconnect electrical power. 11. Verify proper glass media placement, operation of fireplace, and any electrical components. FIGURE 8.3 Control Board Removal and Installation #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 43: Electrical Information

    LIGHT KIT GREEN BLACK (MAIN) BATTERY PACK 6V DC ORANGE (with 1 amp fuse) (PILOT) ON/OFF ROCKER SWITCH GROUND FIGURE 9.1 Komfort 8K Wiring Diagram #SLA-36 #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022 R.12 March 2022...
  • Page 44: Sl42-028 Optional Fan Kit

    See FIGURE 9.1 on page 43. left (FIGURE 9.2). 10. Reinstall the glass frame assembly and safety barrier. FIGURE 9.2 Steps 3 and 4 FIGURE 9.3 Steps 5 through 9 #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 45: Operating Instructions

    This fireplace may produce noises of varying degree as it heats and cools due to metal expansion and contraction. This is normal, and does not affect the performance or longevity of the fireplace. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 46: Setup Komfort 8K1 Control Module

    There is a cut-out opening located on the control module housing that holds the black and red wiring connectors for the back-up battery pack. See FIGURE 10.1. FIGURE 10.1 Back-up Battery Connection #SLA-36 #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022 R.12 March 2022...
  • Page 47: Komfort 8K1 Control System Ignition Sequence

    • Error caused by sense and/or igniter lead disconnected. Verify that the pilot sensor rod, igniter rod, and hood are clean. #SLA-36 #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022 R.12 March 2022...
  • Page 48: Remote Control Operation

    (5) seconds. Press any button to in ON mode. resume full functionality. In idle mode, only active functions will show on the screen. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 49 ON. Only active functions will be displayed when the remote control is ON. • The transmission indicator icon will flash and a single beep will confirm the reception of the command. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 50 If the room temperature rises above the set temperature, the fireplace will shut down the main burner. The fireplace will turn back on after the room temperature drops below the set temperature. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 51 The transmission indicator icon will flash to confirm the intensity. reception of the command. • The transmission indicator icon will flash and a single beep will confirm the reception of the command. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 52: Adjustment

    (0.67 - 2.49 kPa) inlet pressure tap (A) to verify the tap is completely sealed. Manometer should read no pressure. Manifold pressure tap Inlet pressure tap FIGURE 11.1 Pressure Check Taps #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 53: Flame Appearance Adjustment

    Lifting (ghosting) ames Venturi settings(s) closed too far. Open venturi(s) slightly OR gas pressure too high - check manometer settings FIGURE 11.3 Flame Appearance and Characteristics FIGURE 11.2 Burner Venturi #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 54 Insert restrictor into the 5” (127mm) exhaust pipe with the tabs pointing towards you. Reinstall termination access panel by inserting tabs in panel into slots in baffle. Secure with (2) screws previously removed. Reinstall all components previously removed. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 55: Troubleshooting

    Control system set to Pilot-on- Set control system to intermittent pilot ignition mode. Refer to section will not extinguish Demand ignition mode 10.8.7, PILOT IGNITION SELECTION on page 49. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 56 Venturi air shutter may need to be opened slightly to allow more air into the gas mix. Refer to section 11.2.1, BURNER VENTURI on page 53. Incorrect vent cap installation Adjust if necessary. Vent cap blockage Remove debris if necessary. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 57 A maximum number of failed Reset Komfort 8K1 control module. Refer to section 10.2, INITIALIZE THE KOMFORT 8K1 CONTROL SYSTEM on page 46. ignitions or flame restorations has been reached #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 58: Maintenance

    7.0, VENTING on page 29. Performed by: Qualified Service Person Frequency: Annually Action: • Examination of the vent system is required. • The flow of combustion and ventilation air must not be obstructed. #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 59: Burner And Pilot System

    It must de-energize the safety shutoff in no more than (30) seconds. FIGURE 13.2 Correct Pilot and Burner Flame Appearance Burner ori ce BURNER PORTS FIGURE 13.1 Burner System #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 60: Replacement Parts List

    SL36-CXSF Convex Screen Front 700-203 Manual Gas Shut-off Valve SL36-BSF Beveled Screen Front Hussong Manufacturing Co., Inc. 204 Industrial Park Drive PO Box 577 Lakefield, MN 56150-0577, USA SLA-36 #SLA-36 HUSSONG MFG. CO., INC. KOZY HEAT FIREPLACES R.12 March 2022...
  • Page 61: Limited Lifetime Warranty

    • All parts and material except the items listed in the 30 day Kozy Heat gas appliance from the date of purchase to the original warranty and any exclusions or limitations that may apply. purchaser, that it is free of defects in materials and workmanship at *Hussong Mfg.

This manual is also suitable for: