9.2.5 Functional test

9.2.6 AP functional test

(Manual)
9. Pull off the thumb turn.
9
Electronic thumb-turn is disassembled.
Perform a function test after each installation and each battery change.
ü
Assembly or battery change completed
Digital Cylinder AX programmed
ü
At least one identification medium authorised
ü
1. Pull hard on the electronic or mechanical thumb-turns.
2. Turn the electronic thumb-turns. The Digital Cylinder AX the AX locking
cylinder must not be tight, nor rotate the tappet.
3. Activate an authorised identification medium.
4. Check that the Digital Cylinder AX engages and pushes out the locking
bit.
9
Mounting or battery change successfully completed.
Carry out a function test:
After assembly
After realignment
After changes to the fastening screw
9. Installation
47 / 158