Failure Code [Ca429] Abnormally Low Level In Water Sensor - Komatsu WA250-6 Shop Manual

Wheel loader
Hide thumbs Also See for WA250-6:
Table of Contents

Advertisement

SEN03843-00

Failure code [CA429] Abnormally low level in water sensor

Action code
Failure code
E01
Contents of
• Low voltage occurred in fuel water sensor
trouble
Action of
• None in particular.
controller
Problem that
appears on
• Water separator monitor does not indicate normally.
machine
Related
• Method of reproducing failure code: Turn the starting switch ON.
information
1 Defective fuel water sensor
Ground fault in wiring har-
2
ness
(Contact with ground circuit)
Possible causes
Short circuit in wiring har-
and standard
3
ness
value in normal
(with another wiring harness)
state
Defective wiring harness
4
connector
5 Defective engine controller
6
40-330
Trouble
CA429
Causes
330 Troubleshooting by failure code (Display of code), Part 3
Failure code [CA429] Abnormally low level in water sensor
Abnormally low level in water sensor
(Engine controller system)
Standard value in normal state/Remarks on troubleshooting
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
E42 (female)
Between (1) and (2)
Between (1) and ground
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between EC1 (female) (14) –
E42 (male) (1) and ground
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness among all pins between EC1
(female) (14) – EC1 (female) (With all con-
nectors of wiring harness disconnected)
Connecting parts among fuel water sensor, engine wiring harness,
and engine controller are suspected. Inspect them directly.
• Loose connector, broken lock, broken seal
• Corrosive, bent, broken, forced-in, or extended pin
• Humidity in connector, entry of dirt or dust, poor insulation
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
EC1 (female)
Between (14) and (47)
Between (14) and ground
1
Resistance
Max. 10 z
Min. 100 kz
Resis-
Min.
tance
100 kz
Resis-
Min.
tance
100 kz
Resistance
Max. 10 z
Min. 100 kz
WA250, 250PZ-6