SEN03834-01
Coupler plunger control system
WA250PZ-6
Outline
The coupler plunger is extracted or retracted
q
by operating the quick coupler attachment
switch to connect and release each attachment
and the coupler.
Operation
When quick coupler attachment switch is in
"Release" position
If the quick coupler attachment switch (1) is set
q
in the "Release" position, quick coupler sole-
noid valve (2) is energized.
If the work equipment (bucket) control lever is
moved to the tilt side, the oil flows into the
head side of coupler plunger (3). Then, coupler
plunger (3) is retracted and the attachment and
coupler are released.
32
10-920
When quick coupler attachment switch is in
"Connect" position
If the quick coupler attachment switch (1) is set
q
in the "Connect" position, quick coupler sole-
noid valve (2) is de-energized.
If the work equipment (bucket) control lever is
moved to the tilt side, the oil flows into the bot-
tom side of coupler plunger (3). Then, coupler
plunger (3) is extracted and the attachment
and coupler are connected.
920 Electrical system, Part 2
Coupler plunger control system
WA250, 250PZ-6
1