Failure Code [Dafrkr] Machine Monitor Can-Net Signal: Disconnection - Komatsu WA250-6 Shop Manual

Wheel loader
Hide thumbs Also See for WA250-6:
Table of Contents

Advertisement

SEN03844-00

Failure code [DAFRKR] Machine monitor CAN-NET Signal: Disconnection

Action code
Failure code
E03
DAFRKR
Contents of
• HST controller cannot get information from machine monitor
trouble
• Turns the centralized warning lamp and alarm buzzer ON.
Action of
• Uses CAN information that was sent from machine monitor before the occurrence of the error.
machine monitor
• If problem is removed, system is returned to normal operating state.
Problem that
appears on
• The monitor does not display normally
machine
Related
• Method of reproducing failure code: Turn the starting switch ON.
information
Defective CAN end point
1
resistance
Possible causes
and standard
value in normal
state
Disconnection in wiring har-
ness
2
(Disconnection or defective
contact in connector)
16
40-340
Failure code [DAFRKR] Machine monitor CAN-NET Signal: Disconnection
Machine monitor CAN-NET Signal: Disconnection
Trouble
(HST controller system)
Causes
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between HST (female) (28),
(38) – L80 (female) (7), (8)
Wiring harness between HST (female) (28),
(38) – L29 (female) (3), (8)
Wiring harness between HST (female) (28),
(38) – EC2 (female) (46), (47)
Wiring harness between HST (female) (28),
(38) – C140 (female) (28), (38)
Wiring harness between HST (female) (28),
(38) – CAN1 (female) (A), (B)
Wiring harness between HST (female) (28),
(38) – CAN2 (female) (A), (B)
340 Troubleshooting by failure code (Display of code), Part 4
Standard value in normal state/Remarks on troubleshooting
CAN1 (male)
Between (A) and (B)
CAN2 (male)
Between (A) and (B)
Resistance
110 – 140 z
Resistance
110 – 140 z
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
WA250, 250PZ-6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wa250pz-675001

Table of Contents