Failure Code [Ca1633] Komnet Datalink Timeout Error - Komatsu WA250-6 Shop Manual

Wheel loader
Hide thumbs Also See for WA250-6:
Table of Contents

Advertisement

SEN03843-00

Failure code [CA1633] KOMNET datalink timeout error

Action code
Failure code
E03
CA1633
Contents of
• Engine controller detected a communication error in the KOMNET communication circuit used for the
trouble
communication between the HST controller and machine monitor.
• Continues the operation from the default mode.
Action of
• Turns the centralized warning lamp and alarm buzzer ON.
controller
• If problem is removed, system is returned to normal operating state.
Problem that
• KOMNET communication information may not be transmitted correctly to cause incorrect operation
appears on
of machine. (Problem depends on failure occurrence location.)
machine
Related
• If failure code [DAJRKR] is indicated simultaneously, carry out troubleshooting for it first.
information
• Method of reproducing failure code: Turn the starting switch ON.
Defective CAN end point
1
resistance
Possible causes
and standard
value in normal
state
Disconnection in wiring har-
ness
2
(Disconnection or defective
contact in connector)
40
40-330
KOMNET datalink timeout error
Trouble
(Engine controller system)
Causes
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
a Prepare with starting switch OFF, then carry out troubleshooting
without turning starting switch ON.
Wiring harness between EC2 (female) (46),
(47) – HST (female) (28), (38)
Wiring harness between EC2 (female) (46),
(47) – L29 (female) (3), (8)
Wiring harness between EC2 (female) (46),
(47) – L72 (female) (22), (32)
Wiring harness between EC2 (female) (46),
(47) – L80 (female) (7), (8)
Wiring harness between EC2 (female) (46),
(47) – CAN1 (female) (A), (B)
Wiring harness between EC2 (female) (46),
(47) – CAN2 (female) (A), (B)
330 Troubleshooting by failure code (Display of code), Part 3
Failure code [CA1633] KOMNET datalink timeout error
Standard value in normal state/Remarks on troubleshooting
CAN1 (male)
Between (A) and (B)
CAN2 (male)
Between (A) and (B)
1
Resistance
110 – 140 z
Resistance
110 – 140 z
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
Resis-
Max. 1 z
tance
WA250, 250PZ-6