Venting

Co-Linear Vent Installations

The fi replace dimensions are shown below.
1. Place the appliance (fi tted with the co-linear adapt-
er) near the fi replace opening but allow space for
manipulating the chimney liners on to the appliance.
2. Drop the 3-inch diameter fl exible liners into the
chimney from outside.
3. Fit the liners to the co-linear adapter paying atten-
tion to inlet and exhaust and move the appliance to
its proper position. Be aware of the minimum liner
bend radius and maximum liner horizontal run as
indicated at right.
4. Fit the termination kit and fl ashing to the exterior of
the chimney.
5. Secure the appliance to the fl oor or wall if necessary.
Rear or Top Outlet Conversion to Co-Linear Liners using
Valor 556CLA Co-Linear Adapter
(Generic co-axial to co-linear adapter boxes may also be used as an
alternate to the 556CLA).
Only for use when retrofi tting a sollid-fuel burning fi replace and chimney.
The appliance must not be connected to a chimney fl ue serving a separate
solid-fuel burning appliance.
Requires 556CLA Co-Axial to Co-Linear Appliance Adapter (or, alternatively, a
generic adapter), two lengths of 3-inch diameter fl exible chimney liner, co-linear
termination kit and fl ashing and either high wind vertical vent terminal cap or a
low profi le vertical termination. Zero Clearance stand-off s and shields supplied with
the heater are not required for this application.
Exhaust Spigot
Gasket
Intake
Outer
Plate
556CLA Kit
Exhaust
14"
556CLA on Rear Outlet

Co-Linear Conversion

3" min.
bend radius
Co-linear
adapter
18" max.
horizontal run
2 x 3" Liners
556CLA
Approved co-linear
termination or approved
co-linear adapter
and approved
2 x 3"
co-axial
Flashing
liners
termination
534
engine
Co-linear
adapter
Co-Linear installation into
existing F/P
556CLA
2 x 3" Liners
14"
556CLA on Top Outlet
Max.
40'
2 x 3"
liners
21