Framing - Valor HORIZON 534JN Installation Manual

Direct vent zero clearance gas fireplace
Hide thumbs Also See for HORIZON 534JN:
Table of Contents

Advertisement

Planning
• A non-combustible hearth is not necessary in front of
this appliance.
• Note that the appliance is installed at the framing
stage and secured to framing using support angles.
See page 24, 26. Wall fi nish is then installed
afterwards over the support angles and up to the
perimeter of the unit.
- 29-3/4" to wall finish
- 30-3/4" when using
645CFV Clearview Front or
673 Edgemont Front
See installation manual
packed with front trim
12
NOTE
When the appliance is installed directly on
carpeting, tile or other combustible material
other than wood flooring, the appliance shall be
installed on a metal or wood panel extending the
full width and depth of the appliance.
Wall Finish
16" min. straight out or off the top venting.
Allow for elbow if rear vent with rise.

Framing

33-3/4" to
header
This is the framing
width. Wall finish
to 32-3/16" wide.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Horizon 534jp

Table of Contents