Installation
Check Operation
Turn the fi replace fl ame up and down using the remote
control to confi rm that the full range of inputs is
achieved—see Appendix B – Remote Control Operation
pages 46–49 for details.
Adjust Aeration (if needed)
Light the fi re and allow the unit to warm up for 10–15
minutes to evaluate the fl ame picture. Burners are
equipped with an ajustable shutter to control primary
aeration. See fi gures below. The shutter is factory-set to
an aeration gap which will give optimum performance
for the vast majority of installations.
Air Shutter
Air Shutter
Slider & Cover
(natural gas)
38
Natural Gas
Close
Open
Close
Open
In some installations, depending of the fuel bed used,
the altitude and other considerations, the fl ame picture
may be improved by adjusting the aeration. The need
for adjustment should be determined ony by operating
the appliance with the fuel bed and window installed
and evaluating the fl ame picture after a 15-minute
warm-up.
Increasing aeration (open) will cause the fl ames to
appear more transparent and blue showing more
ceramic eff ects glow.
Decreasing aeration (close) will cause fl ames to appear
more yellow or orange showing less ceramic eff ects
glow.
Too little aeration may result in black carbon forming and
dropping into the fi rebox.
Flashback shield
(propane only)
Air Shutter Slider
(propane gas)

Burner aeration

Propane Gas
Close
Open