Installation Planning
 WARNING
Ensure weight of wall above is
NOT carried by the appliance.
Zero
clearance
standoffs
11-1/4"
(285 mm)
5-1/4"
(133 mm)
17"
(432 mm)
11"
(279 mm)
Combustible
framing material
HeatShift plenum framing required (front or sides);
see instructions packed with HeatShift kit.
Framing—Minimal
Combustible framing material
except if using HeatShift front
outlet plenums LDK1 or LDK4:
in this case steel stud required
under outlet opening - see
instructions packed with
HeatShift kit
1/2" (13 mm) non-combustible
cement board required.
(May be covered with max. 3/4"
(19 mm) combustible finish).
Combustible projections must
otherwise conform to allowable
mantel projections - see
Clearances to Combustible
Projections section in this manual.
Max. 1-1/4" (32 mm)
thickness combustible
wall finish allowed
20" (508 mm) min.
15