Setting
Sign
Value
S-P
18
Speed / Position mode switching (OFF: Speed, ON: Position)
S-T
19
Speed / Torque mode switching (OFF: Speed, ON: Torque)
T-P
20
Torque / Position mode switching (OFF: Torque, ON: Position)
Emergency stop. It should be contact "b" and normally ON or a fault (ALE13) will
EMGS
21
display.
Reverse inhibit limit. It should be contact "b" and normally ON or a fault (ALE14) will
CWL
22
display.
Forward inhibit limit. It should be contact "b" and normally ON or a fault (ALE15) will
CCWL
23
display.
Reference "Home" sensor. When ORGP is activated, the drive will command the motor
ORGP
24
to start to search the reference "Home" sensor. [see P1-47]
Torque limit - Reverse operation (Torque limit function is valid only when P1-02 is
TLLM
25
enabled)
Torque limit - Forward operation (Torque limit function is valid only when P1-02 is
TRLM
26
enabled)
Move to "Home". When SHOM is activated, the drive will command the motor to move
SHOM
27
to "Home". [see P1-47]
INDEX0
28
Feed step selection input 0 (bit 0)
INDEX1
29
Feed step selection input 1 (bit 1)
INDEX2
30
Feed step selection input 2 (bit 2)
INDEX3
31
Feed step selection input 3 (bit 3)
INDEX4
32
Feed step selection input 4 (bit 4)
MD0
33
Feed step mode input 0 (bit 0)
MD1
34
Feed step mode input 1 (bit 1)
MDP0
35
Manually continuous operation
MDP1
36
Manually single step operation
Forward JOG input. When JOGU is activated, the motor will JOG in forward direction.
JOGU
37
[see P4-05]
Reverse JOG input. When JOGD is activated, the motor will JOG in reverse direction.
JOGD
38
[see P4-05]
Step up input. When STEPU is activated,
STEPU
39
the motor will run to next position.
Revision January 2009
Chapter 7 Servo Parameters|ASDA-AB Series
Digital Input Function Description
When the drive is in Pr mode, if users set P1-33 to
2, 3 and 4 (Feed step control mode), feed step
control function are provided (1~32 steps). [see
section 12.6 Feed Step Control]
Mode function:
MDPn
Status
1
2
OFF
3
4
ON
Available when the drive is in Pr mode
and users must set P1-33 to 5 and 6.
(Internal auto running mode) [see section
12-7 Internal Auto Running Mode]
MD1
MD0
Explanation
Torque
OFF
OFF
decrease
Feed step
OFF
ON
position mode
ON
OFF Homing mode
Emergency
ON
ON
stop
X
X
Don't care
CW manual
OFF
ON
operation
CCW manual
ON
OFF
operation
X
X
Don't care
7-91