Servo Output Status Display - Delta Electronics AC Servo Drive ASDA-AB User Manual

Asda-ab series advanced ac servo drive for general purpose applocations
Table of Contents

Advertisement

Chapter 7 Servo Parameters|ASDA-AB Series
P0 - 17
SVSTS

Servo Output Status Display

Default: N/A
Applicable Control Mode: ALL
Unit: N/A
Range: N/A
Settings:
This parameter is used to display the digital output signal of the servo drive. The servo output
status display will show in hexadecimal format.
Bit0: SRDY (Servo ready)
Bit1: SON (Servo On)
Bit2: ZSPD (At Zero speed)
Bit3: TSPD (At Speed reached)
Bit4: TPOS (At Positioning completed)
Bit5: TQL (At Torque limit)
Bit6: Reserved
Bit7: Reserved
Bit8: OLW (Output overload warning)
Bit9: WARN (Servo warning activated)
Bit10: CMDOK (Internal position command completed)
Bit11: Reserved
Bit12: Reserved
Bit13: ALRM (Servo alarm activated)
Bit14: BRKR (Electromagnetic brake control)
Bit15: HOME (Homing completed)
The servo output status display can be monitored through communication also.
7-26
Communication Addr.: 0011H
Related Section:
Table 7.B
Revision January 2009