P2 - 33▲
INF
Easy Setting of Input Filter
Default: 0
Applicable Control Mode: ALL
Unit: N/A
Range: 00 ~ 19
Settings:
•
A: Speed selection
A=0
A=9
•
B=1: Enable this function
P2 - 34
SDEV
Overspeed Warning Condition
Default: 5000
Applicable Control Mode: S
Unit: r/min
Range: 1 ~ 5000
Settings:
This parameter is used to set the over speed condition of the drive fault code. (See P0-01)
P2 - 35
PDEV
Excessive Error Warning Condition
Default: 30000
Applicable Control Mode: Pt, Pr
Unit: pulse
Range: 1 ~ 30000
Settings:
This parameter is used to set the excessive error condition of the drive fault code (See P0-01) .
As for the proportion value setting of position excessive error warning condition, please refer to
P2-63.
Revision January 2009
A
B
not used
Low speed
High speed
Chapter 7 Servo Parameters|ASDA-AB Series
Communication Addr.: 0221H
Related Section:
Section 6.3.6
Communication Addr.: 0222H
Related Section: N/A
Communication Addr.: 0223H
Related Section: N/A
7-63