13.10   Transmitting programming jobs to a locking device via RF-Stick
Steps
1. Take your PC and the connected RF-Stick to the locking device to which you wish to
transmit programming jobs.
If you need to transmit programming jobs to multiple locking devices, you can
freely select the order in which you visit them.
2. Hold the RF-Stick-Master briefly in the reading field of the locking device.
The RF-Stick-Master is accepted.
3. The locking device now searches for an RF-Stick in its vicinity. Transmission begins once
the RF-Stick is detected.
The distance between the locking device and RF-Stick must not exceed ten metres.
Programming jobs are being transmitted.
The following occurs during transmission:
- All programming jobs for this locking device are transmitted to the locking device. During
the programming process, the programming status display indicates the progress as a
percentage.
- All events stored in this locking device that are not yet present in the OMEGA Client are
copied to the OMEGA Client.
- The clock is set.
If no programming jobs are present, only the events are copied and the clock is set.
In this case the locking device does not flash during transmission.
4. After the transmission, the RF-Stick and locking device are disconnected automatically.
Transmission was completed successfully.
After transmission is complete, the programming job is removed from the 'Programming
status' list.
Troubleshooting:
Signal
After step 2:
1x
long red
+ beep
Page 80 of 84
Cause
Solution
The locking device cannot
Check that the RF-Stick is properly connected and take it closer
detect an RF-Stick in the
to the locking device, then try to transmit the programming
vicinity.
jobs again.
Signal
1x short green
Short green
signals
1x
long green
+ beep