8.7 Opening modes of the locking devices
8.7.1 About the different opening modes of the locking devices
Block
A locking device in block mode remains constantly uncoupled, i.e. the door cannot be opened.
mode
Access is no longer possible, even with authorised locking media.
Release
A locking device in release mode remains constantly coupled, i.e. the door can be opened at
mode
any time without having to use a locking medium.
Emergency
Emergency mode is similar to release mode: the locking device remains constantly coupled so
mode
that the door can be opened at any time without having to use a locking medium.
Unlike release mode, however, emergency mode cannot be cancelled again by the Release-
Master but only by the Emergency-Key and has the highest priority of all the opening modes
(see
"Hierarchy of opening modes"
Normal
A locking device in normal mode can be opened with an authorised locking media.
mode
Unauthorised locking media are rejected.
8.7.2 Hierarchy of opening modes
1 = highest priority, 7 = lowest priority
1
Emergency mode (activated by Emergency-Key)
2
Block mode (activated by Block-Master)
3
Block time (activated by time profile in OMEGA Client)
4
Release mode (activated by Release-Master)
5
Enable time (activated by time profile in OMEGA Client)
7
Normal mode (opening enabled by locking medium)
RFID furniture lock
8.7   Opening modes of the locking devices
below).