ASTRO ATS-309 Operator's Manual page 72

Table of Contents

Advertisement

PROGRAMMING THE TABBER
11. Press BACK one time to return to
"Select option to edit" screen and
select Position.
12. Each of the two tab positions must be
entered. Position of tab is measured
from lead edge of piece (exit end)
separately. Begin by measuring piece
length and deciding where first tab will
be placed. In this example, Post Office
requires first tab be positioned less than
1/2" from bottom of piece. Press Tab 1.
13. Position of Tab 1 should not be greater
than 1.0" from right or bound edge.
Enter 0.900" using Number keys on
Control Panel. Press SAVE key.
14. Select Tab 2 and enter position for
Tab 2 from lead edge. This tab should
be positioned a distance of less than 1"
from trailing edge or left edge of piece.
If piece is 10.5" long and you are using
1-1/2" tabs as required, setting would
be 1.500", plus 0.900" subtracted from
10.5" length, which would be 8.100".
Enter that number using Number keys, then SAVE key. Press BACK key.
15. Press BACK until you return to
"Select Setup Option" screen and
Select V-Tab.
68