ASTRO ATS-309 Operator's Manual page 66

Table of Contents

Advertisement

PROGRAMMING THE TABBER
10. Pitch of tab is distance measured from
top of one tab to top of next tab. This is
done by selecting Pitch from "Select
option to edit" screen. Measure
distance from top of one tab to top of
next tab. In this case, it was 1.630".
Then add 0.01" for a total of 1.64".
Enter that number using number keys
on Control Panel, then pressing SAVE key.
11. Press BACK one time to return to
"Select option to edit" screen and
select Position.
12. Each of two tab positions must be
entered. Position of tab is measured
from lead edge of piece (exit end)
separately. Begin by measuring piece
length and deciding where first tab will
be placed. In this example, Post Office
requires that first tab be positioned less
than 1/2" from bottom of piece.
Press Tab 1.
13. Position of Tab 1 should not be greater
than 1/2" from bottom (lead) edge.
Enter 0.4900" using Number keys on
Control Panel, press SAVE key and
then BACK key.