ASTRO ATS-309 Operator's Manual page 67

Table of Contents

Advertisement

14. Select Tab 2 and enter position for
Tab 2 from lead edge. This tab should
be positioned at a distance of less than
1" from trailing edge of piece. If piece
is 8.0" long and you are using 1-1/2"
tabs as required, setting would be
1.500" plus 0.900" subtracted from 8.0"
length which would be 5.600". Enter
that number using Number keys, then press SAVE key. Press BACK key.
15. Press BACK until you return to "Select
Setup Option" screen. Select V-Tab.
16. Then select V-Tab 1. Follow Step 5 and
calibrate V-Tab voltage for Head 1.
17. Use BACK key to return to
"Select Setup Option" screen and
choose Manual again.
18. Select Head #1.
PROGRAMMING THE TABBER
63