Y-Repeater
10.3

Switching Times Y-Repeater

10.3.1

General Information

Fig.10-2:
Dimensions of the Y-repeater - side view
NOTICE
To guarantee an UL-compliant operation, the Y-repeater is to be operated only
within an UL-registered housing.
If an active operator terminal is disabled it takes some seconds until the enabled
screen can be operated. The time interval is the so-called "switching time". This
switching time depends on whether USB devices are connected to "XUSBx"
connections and on the used USB mode.
In order to get faster values in the standard USB mode, all connected VDPs
are to be connected in the standard USB mode. The standard USB mode can
be used up to a cable length of 30 m, see also chapter 7.2.3 "S1 DIP switch".
The values specified in this chapter are valid for devices from index 201 and
higher (see type plate of the Y-repeater).
DOK-SUPPL*-VDP*08.3***-PR02-EN-P
Rexroth IndraControl VDP 08.3/40.3 Operator Terminal
Loss of UL compliance if operated without UL-
registered housing.