Description Of The Interfaces; Cdi Interfaces; Cable Connections And Cable Types Allowed - Bosch Rexroth IndraControl VDP 08.3 Manual

Operator terminal
Table of Contents

Advertisement

DOK-SUPPL*-VDP*08.3***-PR02-EN-P
Rexroth IndraControl VDP 08.3/40.3 Operator Terminal
10.4.2

Description of the Interfaces

10.4.3

CDI Interfaces

10.4.4

Cable connections and cable types allowed

Cable lengths
Designation
Connection type
at the housing
X1S1
24 V voltage supply
Digital 24 V input
XSER
CDI interface to the
control cabinet PC
XVID
XSER1
CDI interface to the
VDP 08.3/40.3 no. 1
XVID1
XSER2
CDI interface to the
VDP 08.3/40.3 no. 2
XVID2
Fig.10-6:
Connections on the Y-repeater
The Y-repeater is connected to the control cabinet PC and to two operator dis‐
plays via the CDI interfaces (XSER, XVID, XSER1, XVID1, XSER2, XVID2).
Connection
XSER, XVID
XSER1, XVID1
XSER2, XVID2
Fig.10-7:
Assignment of the three CDI interfaces
The chapter "Ordering Information" contains connecting cables of different
lenghts.
The cable lengths allowed at the Y-repeater depend on the display resolution
set (depends on the VDP).
A cable length of 100 m max. (from control cabinet to VDP) is possible when
using a XGA resolution. Also refer to the different operation modes of the CDI
interface.
The cables on the Y-repeaters may not exceed the following lengths:
Cable lengths
Cable lengths between the
control cabinet PC and the
VDP
without Y-repeater
Cable lengths between con‐
trol cabinet PC and Y-repeat‐
er
Bosch Rexroth AG
Connector type (inte‐
grated)
Phönix connector strip,
4-pin,
MC1,5/4-
G-3,5THT
Two RJ45 female con‐
nectors
Two RJ45 female con‐
nectors
Two RJ45 female con‐
nectors
Function
CDI interface to the control cabinet PC
CDI interface to the VDP 08.3/40.3 no. 1
CDI interface to the VDP 08.3/40.3 no. 2
SVGA
XGA
800 × 600 pix‐
1024 × 768 pixels
els
< 80 meters
< 70 meters
< 80 meters
< 70 meters
63/81
Y-Repeater
Mating connector or
cable from outside
Phönix female connec‐
tor strip,
4-pin, FK-MCP 1,5/4-
ST-3,5
Two RJ45 connectors
Two RJ45 connectors
Two RJ45 connectors
SXGA
1280 × 1024 pix‐
els
< 60 meters
< 60 meters

Hide quick links: