Ce Marking; Declaration Of Conformity - Bosch Rexroth IndraControl VDP 08.3 Manual

Operator terminal
Table of Contents

Advertisement

DOK-SUPPL*-VDP*08.3***-PR02-EN-P
Rexroth IndraControl VDP 08.3/40.3 Operator Terminal
Emergency stop button - standards
4.4.2

CE Marking

Declaration of Conformity

Standard
EN 60 664-1
EN 61 131-2
EN 61 131-2
ISO 13 850
EN 60 529
EN 60 068-2-6
EN 60 068-2-27
EN 60 721-3-1 and
EN 60 721-3-3
Fig.4-4:
Used standards
The emergency stop button is disclosed by the manufacturer as safety com‐
ponent according to machinery directive 2006/42/EC (annex V-10, emergency
stop devices). The compliance with the directive is proven by adherence to the
following European standards:
IEC 60204-1 (safety of machinery – electrical equipment of machines)
IEC 60947-5-1/5 (requirements for control circuit devices, requirements
for emergency stop devices)
ISO 13850 (safety of machinery - emergency stop - principles for design)
According to DIN EN ISO13849-1 the B10d value is:
Mechanics
B10d = 250 000
exclusion of failure at < 6050 switching cy‐
cles
Fig.4-5:
Emergency stop button, B10 d value, service life
The electronic products described in the project planning manual comply with
the requirements and goals of the following EC guideline and with the agreed
European standards:
EMC guideline 2004/108/EC
The electronic products described in the project planning manual comply with
the requirements on the operation within the industrial environment:
Bosch Rexroth AG
Meaning
Overvoltage category II
Requirements regarding the 24 V outputs
Requirements on the 24 V power supply
Machine safety, EMERGENCY STOP devices
Degrees of protection (including housings and installation
compartments)
Vibration test
Shock test
Climatic class
Electrics
B10d = 5 000 000
exclusion of failure at < 6050 switching cy‐
cles