Control Unit

CAUTION:
The control unit must be installed on a stable base.
The control unit has three internal blow-out fuses.
The operation voltage is 100V to 240V at 50Hz / 60Hz.
Two fuses (F1 and F2) for the input AC power
• F1 for the protected phase and
• F2 for the neutral line.
Fuse F3 protects the neutral line of the safety relay.
Note:
The phase line of the safety relay is protected internally by the
laser power supply unit.
The control unit needs at least 80mm free space on all sides for proper
ventilation.

Power supply

The mains supply is provided by a 5m mains cable, which is connected to
the control unit via a four-pole plug. It may be necessary to install a suitable
AC mains plug to the loose end of the cable, connected as follows:
Green/Yellow
Ground/Earth
Black 2
Neutral
Black 1
Live
Install the plug nearby the controller so that the controller can be easily
unplugged in case of emergency. Use a plug with the following
specifications:
Plug is not locked
• 110V / 230V
• 50/60Hz
• max. 20A.
The equipment specifications, listed on the name plate (voltage, frequency,
power consumption) are to be observed under all circumstances. The
correct fusing is to be made external to the laser system
The mains power connection must always be easily accessible during
operation in order to quickly remove the power from the laser system when
required.
The control unit contains the electrical components necessary for
distribution of the correct voltages to the laser head.
2-6
INSTALLATION INSTRUCTIONS
Do not expose the control unit to any vibrations.
EPT009665 Issue 2 May 2015