HEALTH & SAFETY
Cable will be subject to high levels of acceleration, torsion and twist, or
combination thereof. If this is a requirement for the integration, please
contact Domino to discuss the application in more detail.
The minimum bend radius for the fibre is r= 75mm.

Interlock Switches

Interlock switches must be fitted to all access guards, preventing access to
the laser output lens and marking area that can be opened without the use
of access tools.
Interlock switches must be wired into the laser control circuit so that the
laser beam is disabled when the guard is removed.

Emergency Off

Integrate the laser into the emergency off circuit of the machine into which
the laser is integrated. Install an emergency off push button near the laser
marking systems which turns off the laser. Connect the emergency off push
button via the interlock circuit to the controller.
EPT009665 Issue 2 May 2015
1-13