Notes: (1) To prevent incorrect connections, different male and female
connectors have been installed and clearly marked (X...).
(2) When connecting the cables, ensure that the plugs are correctly
aligned to prevent damage to the pins.

Laser Unit F220i Connections for F-Series

Mains
Inter-connection
Mains in
Mains In
Input of main power
Mains In
Mains Interconnection
Input of main power - connection to BCP7
Controller
X24
Laser Data Interconnection
To be connected to the X24 connector of the
core controller. Use the specified cable labelled
with X24 on both ends.
X66
Connector to CO
Optional connector to a shutter mounted on a
CO
laser. This connector remains unused in
2
case of fibre laser
X68
Interlock / Process Start Interconnection
To be connected to the X29 connector of the
BCP7 controller. Use the specified cable
labelled with X29 and X68 on the ends.
X69
X69 Guard door / Interlock Contacts
Shutter and laser start command, optional door
lock.
2-12
INSTALLATION INSTRUCTIONS
X24 X66 X69 X68
Laser Shutter
2
EPT009665 Issue 2 May 2015