COMPRESSED AIR CONNECTION, LENS

The scanner head can be equipped with a connection for compressed air.
Compressed air keeps the objective lens free from dust. It requires a 6mm
diameter hose.
To fit the compressed air hose:
(1) Push the sleeve nut over the hose
(2) Push the hose onto the air connector and tighten the sleeve nut.
CAUTION:
Compressed air connector at scanner head
(use the connector on the left or on the right side of the scanner head)

FUME EXTRACTION SYSTEM

Domino recommend installing the DPX500, DPX1000, DPX1500 or the
DPX2000 fume extraction and purifier system. These are designed to
protect personnel from hazardous dust and fumes that may be produced
by the laser marking process.
The DPX1000 is a general purpose fume extraction system that removes
particulates. The DPX2000 fume extraction system has an additional filter
and a chemical pad to remove odours and toxic gases. The DPX500,
DPX1000, DPX1500 and DPX2000 will be equipped with a connector for
the Domino F-Series Laser System.
WARNING:
For details, see the manual included with the Fume Extraction system.
2-52
INSTALLATION INSTRUCTIONS
Only clean and dry compressed air, free of oil,
should be used, to avoid damage to the lens.
When printing onto PVC material, the DPX2000
Extractor should be used due to the toxic and
corrosive gases expelled during the process.
EPT009665 Issue 2 May 2015