Error Register; Table 72 Error Register (Index 0X1001) - WAGO 765-1202/0100-0000 Product Manual

I/o system field 16-channel digital input/output; ethercat; 24 v dc; 2.0 a; 8 × m12 connection
Table of Contents

Advertisement

765-1202/0100-0000
IO-Link Event Code Description of the Error Function
0x6321
0x6350
0x7700
0x7701 – 0x770F
0x7710
0x7711
0x8C00
0x8C01
0x8C10
0x8C20
0x8C30
0x8C40
0x8C41
0x8C42

11.2.2 Error Register

The error register can be accessed in the object dictionary of the EtherCAT
index 0x1001.
Index
0x1001
Product manual | Version: 1.0.0
16DIO FLD EC DC 24V 2.0A
on the Connected IO-Link Device
Missing parameter(s)
Parameter change
Wire break on a lower-level device
Wire break of lower-level device
1...15
Short circuit
Grounding fault
Technology-specific application error
Simulation active
Value range of a process variable ex-
ceeded
Measurement overrange
Process variable value below value
range
Maintenance required
Maintenance required
Maintenance required
Name
Explanation
Error Register
Error Register Object
Bit 0 = 1: Generic error
Bit 1 = 1: Current error (SSC or
ASC)
Bit 2 = 1: Voltage error (LVS or
LVA)
Bits 3–6: reserved
Bit 7 = 1: Internal module error
(IME)
Corrective Action on the Connected
IO-Link Device
Check datasheet
Check configuration
Check installation
Check installation
Check installation (device)
Check installation
Reset device
Check operating mode
Process data insecure
Check application
Process data insecure
Cleaning
Refill
Replacement of wear parts
Table 72: Error Register (Index 0x1001)
Type
Flag
Default
UINT32
RO
0x00000000
Diagnostics
®
slave under
89

Advertisement

Table of Contents
loading

Table of Contents