Port Alert Configuration - General DataComm SC-ADT 8 Port Installation & Operation Manual

Table of Contents

Advertisement

Additional Features

Port Alert Configuration

1. To review the available port alert commands, type: configure ports alert ?
The following Help screen appears.
___________Help for "configure ports alert "______________________
add
clear
copy
delete
ignore-case
match-case
2. Enable the port monitor by tying the following commands:
configure ports monitor enable port
3. Add a port alert string (up to 30 characters) by typing the following command:
configure ports alert add port
4. Continue to add port alert strings to the same port if needed. Up to five alert strings are allowed
per port.
5. Configure the port to select for forwarding either case-sensitive matches (default) or as case-
insensitive matches. Case-sensitive matches have the least impact on throughput since the SC-
ADT will not convert case mismatches.
(Default) To configure the port for case-sensitive matches with the attached device, type:
configure ports alert match-case port[#]
To configure the port for case-insensitive matches with the attached device, type:
configure ports alert ignore-case port[#]
6. To check the port alert configuration for the port, type: show ports alert port[#]
An example display is shown below.
Port alert info for port8
---------------------------------------------------------------
Port Description: ACME Model 1
Match Case: NO
Monitor State: ON
Port alert compare strings:
------------------------------
"error"
"boot"
7. Repeat
step 2.
of the alert strings configured for one port to another port as follows:
Type configure ports alert copy port[#] port[#]
(where the first argument is the "from" port number, followed by the "to" port number).
Type Y at the confirmation prompt to copy the alert string as designated.
076R172-000
Issue 6
Add port alert string; requires 2 parameter(s)
Clear all alert strings for a port; requires 1 parameter(s)
Copy alert strings from port to port; requires 2 parameter(s)
Delete port alert string; requires 2 parameter(s)
Ignore case of port alert strings; requires 1 parameter(s)
Match case of port alert strings; requires 1 parameter(s)
through
step 6.
for each port individually, as needed. As an alternative, copy all
SpectraComm ADT
Installation and Operation Manual
Port Monitoring & Port Alerts
[#] or all
[#] ["quoted string"]
5-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sc-adt 16 portSc-adt 32 portSc-adt 16 por

Table of Contents