Monitoring Features; System Message Log - General DataComm SC-ADT 8 Port Installation & Operation Manual

Table of Contents

Advertisement

Additional Features

Monitoring Features

Each System Message or Alarm log entry is time-stamped with a relative System Up Time (default)
or with GMT, if so configured (refer to
an ACL Violation log, Port Connect/Disconnect log, and a Modem Activity log which can be
enabled/disabled as follows:
To enable logging of port connect/disconnect messages, type:
configure ports log enable
To enable logging of ACL violations, type:
configure acl log enable

System Message Log

The System Message log shows a history of the last 100 SYS MSG events saved to the log. Use this
log to examine link status, diagnostic test activity, etc. The System Message log is not saved when
the unit reboots.
To show the last 100 logged system events, type:
show log sysmsg
To clear the system message log, type:
clear log sysmsg
### -----------------------------Description----------------------------------
11: TELNET connected to port2(GDC V34 ext modem) by username: jake (SysUp 4 days
0 hours 47 mins 46 secs)
10: TELNET closed to port2: GDC V34 ext modem (SysUp 4 days 0 hours 47 mins 23
secs)
9: TELNET connected to port2(GDC V34 ext modem) by username: jake (SysUp 4 days
0 hours 45 mins 44 secs)
8: TELNET closed to port3: SC(SysUp 4 days 0 hours 44 mins
39 secs)
7: TELNET connected to port3(SC) by username: gdc (SysUp 4 days 0 hours 44 mins
7 secs)
6: TELNET closed to port3: SC(SysUp 4 days 0 hours 43 mins
41 secs)
5: TELNET connected to port (SC) by username: jake (SysUp 4 days 0 hours 25 mins
01 secs)
4: TELNET closed to port3: SCM13 term serv) by username: jake (SysUp 0 days
0 hours 30 mins 52 secs)
3: TELNET connected to port3(SC M13 term serv) by username: jake (SysUp 0 day0
0 hours 5 mins 51 secs)
2: ethernet0 (AlphaLAN) line protocol set to UP (SysUp 0 days 0 hours 0 mins
0 secs)
1: SYS MSG logging started (SysUp 0 days 0 hours 0 mins 0 secs)
Figure 5-9
5-14
Time Protocols