IN100 Series
Mortise Lock
Installation Instructions
10
Lock Self-Test LED Indications
After replacing batteries, a Power on Self Test (POST) is performed. The result is indicated using a series of red
Error in lock is an indication -10 quick (125ms) red blinks, that either new batteries are not at right voltage or a
backward battery has been installed; battery not fully charged; energy counter not reset or no Power on self-
test performed.
maintenance required
1 red (1s) + 1 green (1s), Power on self-test passed. See table below.
1 red (1s) + 3 blinks (500ms, green or red), at least one test failed (red). See table below.
If a fatal error is detected, lock will enter an Error state and continuously indicate fatal error. Lock will not read
cords or unlock.
MECHANICAL ERROR
1-800-810-WIRE • www.sargentlock.com • A8190E
and green LED flashes as described by figures below:
Battery Not Fully Charged
Error in lock,
POST Successful
FATAL ERROR
CABLE ERROR
FATAL ERROR
CABLE ERROR
MECHANICAL ERROR
Ten red flashes (.125 sec. each)
(Repeated every 10 sec. if lock can't close)
Test Pass
One red, one green flash
(1 second)
Test Fail
1 sec
0.5 sec
Tests core functionality.
MCUs, memory and internal
communication, etc.
Tests communication between different
parts in system, i.e. different boards
connected with a wire.
Test related to moving parts of lock.
21
0.5 sec
0.5 sec