Sargent ASSA ABLOY IDP-H1 Installation Instructions Manual

Advertisement

Quick Links

A8132C
05/15
Copyright © 2015, Sargent Manufacturing Company, an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Sargent Manufacturing Company is prohibited.
IDP
H1
-
HARMONY
Mortise Lock
Installation Instructions

Advertisement

Table of Contents
loading

Summary of Contents for Sargent ASSA ABLOY IDP-H1

  • Page 1 HARMONY Mortise Lock Installation Instructions A8132C 05/15 Copyright © 2015, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.
  • Page 2: Table Of Contents

    Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT Manufacturing makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.
  • Page 3: General Description

    (LX) and auxiliary bolt (AX), offering added security and improved aesthetics. *Sargent Manufacturing Company (New Haven, CT) 2015 U.S. Patents D601,001S; D601,002S; D601,003S; D602,762S; Patent Pending HID and Edge are trademarks or registered trademarks of HID Global Corporation.
  • Page 4: Features

    Harmony Series IDP-H1 Mortise Lock Features Wiegand Access Control System • Complete monitoring of door via integrated lock: • RX Setting (DIP-Switch Configurable for N/O, N/C and handing) • Door Position integrated with lock body; monitors Secured/Unsecured • Operates from 12 to 24VDC •...
  • Page 5 Harmony Series IDP-H1 Mortise Lock Parts Breakdown (Continued) Left Hand Reverse Door (Shown) ITEM PART # Description Req. 52-5188 Outside Harmony Escutcheon With Cylinder Prep 52-5189 Outside Harmony Escutcheon Without Cylinder Prep 52-0796 Outside Weather Gasket 52-0795 Inside Weather Gasket 52-5218 Mounting Plate Assembly 52-5236...
  • Page 6: Installation Instructions

    Harmony Series IDP-H1 Mortise Lock Installation Instructions 1 Door Preparation A. Verify Hand and Bevel of Door Stand on outside of locked door when determining door hand. Left Hand Left Hand Right Hand Right Hand Hinges Left. Reverse Bevel Hinges Right. Reverse Bevel Open Inward.
  • Page 7 Harmony Series IDP-H1 Mortise Lock 2 How to Change Hand of Lock body A. Reverse Lock Hand Red surface of locking piece must face the outside/locked side of door. To rotate locking Right Hand piece (Fig. 2A): Lock Shown 1. Position lock body with red surface of locking piece visible.
  • Page 8 Harmony Series IDP-H1 Mortise Lock 4 Install Lock body 1. Wires and connectors go into the mortised area and out of the inside cylinder hole. 2. Insert mortise lock body into mortise door preparation. 3. Carefully feed wires from mortise lock through the non-cylinder side hole of the door preparation.
  • Page 9 Harmony Series IDP-H1 Mortise Lock 5 Outside Escutcheon and Inside Mounting Plate Installation (Continued) 2. Feed the reader cable located on the back of the outside escutcheon through the door prep. Remember, the outside gasket must be used when installing Harmony in an outdoor application (Fig.
  • Page 10 Fig. 7A 9 Outside Cylinder Installation 1. Verify orientation of cylinder so that SARGENT logo is right-side up (Fig. 8A). 2. Withdraw the key about 25% out of the cylinder before inserting into the escutcheon (Fig 8B). NOTE: Use lever handle holes to manipulate mortise to ease thread engagement of cylinder.
  • Page 11 Harmony Series IDP-H1 Mortise Lock 10 Install Outside Lever and Inside Adapter Plate Assembly 1. With outside lever horizontal, insert the mounting post through outside of door and lock body. Make certain the lever spindle is properly engaged inside the lock body (Fig 9A). 2.
  • Page 12 Harmony Series IDP-H1 Mortise Lock 12 Position Outside Wires Please follow these steps prior to installing inside escutcheon assembly to prevent any damage caused by pinching wires: 1. Insert the ElectroLynx connectors (8 and 4-pin) and establish their position inside (and through) the door prep (Fig.11A). 2.
  • Page 13 Harmony Series IDP-H1 Mortise Lock 14 Install Inside Rose and Inside Lever Assembly 1. Rotate the inside rose - first counter clockwise Inside of Door to seat the threads and then, clockwise to securely tighten. 2. Slide lever handle onto spindle until fully seated.
  • Page 14: Wiring Diagrams

    ACCESS CONTROL DEVICES: Harmony IDP-H1 Mortise, ElectroLynx wire Color / Function assignments 12VDC WIE- WIE- RX (NO/ EGND 12/24 VDC Reader Power GAND GAND (COM) (NC) (COM) (LOCK RELAY SARGENT - DATA_1 DATA_0 REF. REF. REF. REF. HARMONY STEP 2A STEP DIA- DIA- SERIES, GRAMS...
  • Page 15 Harmony Series IDP-H1 Mortise Lock Typical Harmony Mortise Application Diagram (12/24VDC System) DIAGRAM #1 – MODE 1: LED WIRE NOT USED = RED LED ON WHEN POWERED Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473) Reader Electronics Requires 12VDC Filtered and Regulated 12/24VDC System •...
  • Page 16 Harmony Series IDP-H1 Mortise Lock Typical Harmony Mortise Application Diagram (12/24VDC System) DIAGRAM #2 – MODE 2: LED WIRE TIED TO GROUND = GREEN LED ‘ON’ WHEN POWERED Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473) Reader Electronics Requires 12VDC Filtered and Regulated 12/24VDC System •...
  • Page 17 Harmony Series IDP-H1 Mortise Lock Typical Harmony Mortise Application Diagram (12/24VDC System) DIAGRAM #3 – MODE 3: LED WIRE TO EAC PANEL = EAC PANEL CONFIGURABLE Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473) Reader Electronics Requires 12VDC Filtered and Regulated 12/24VDC System •...
  • Page 18: Mechanical Operational Check

    Harmony Series IDP-H1 Mortise Lock Mechanical Operational Check For 82280-82283 & 82270-82273 Function mortise locks with cylinders: 1. Insert key into cylinder and rotate: There should be no friction against lock case, wire harness or any other obstructions. 2. The key will retract the latch: Key should rotate freely. 3.
  • Page 20 New Haven, CT 06511 USA 800-727-5477 • www.sargentlock.com Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets.

Table of Contents