Lock Self-Test Led Indications - Sargent ASSA ABLOY IN100 Series Installation Instructions Manual

Hide thumbs Also See for ASSA ABLOY IN100 Series:
Table of Contents

Advertisement

IN100 Series
Cylindrical Lock
Installation Instructions
10

Lock Self-Test LED Indications

After replacing batteries, a Power on Self Test (POST) is performed. The result is indicated using a series of red and
Error in lock is an indication -10 quick (125ms) red blinks, that either new batteries are not at right voltage or a
backward battery has been installed; battery not fully charged; energy counter not reset or no Power on self-test
performed.
maintenance required
1 red (1s) + 1 green (1s), Power on self-test passed. See table below.
1 red (1s) + 3 blinks (500ms, green or red), at least one test failed (red). See table below.
If a fatal error is detected, lock will enter an Error state and continuously indicate fatal error. Lock will not read cards
or unlock.
MECHANICAL ERROR
A8189D • 800-810-WIRE (9473) • www.sargentlock.com
green LED flashes as described by figures below:
Battery Not Fully Charged
Error in lock,
POST Successful
FATAL ERROR
CABLE ERROR
FATAL ERROR
CABLE ERROR
MECHANICAL ERROR
Ten red flashes (.125 sec. each)
(Repeated every 10 sec. if lock can't close)
Test Pass
One red, one green flash
(1 second)
Test Fail
1 sec
0.5 sec
Tests core functionality.
MCUs, memory and internal
communication, etc.
Tests communication between different
parts in system, i.e. different boards
connected with a wire.
Test related to moving parts of lock.
19
0.5 sec
0.5 sec

Advertisement