Proline Prosonic Flow 91
Endress+Hauser
11.15 Group CONFIG. CHANNEL
Functional description CONFIG. CHANNEL
SENSOR TYPE
Options:
W-CL-1F-L-B
W-CL-2F-L-B
W-CL-1F-L-C
W-CL-05F-L-B
W-CL-1F-M-B
W-CL-2F-M-B
Factory setting:
W-CL-2F-L-B
SENSOR
Use this function to select the configuration for the ultrasonic clamp-on sensors.
CONFIGURATION
Options:
NO. TRAVERSE: 1
NO. TRAVERSE: 2
NO. TRAVERSE: 4
Factory setting:
NO. TRAVERSE: 2
!
• 1 traverse for nominal diameters larger than DN 600, for certain plastic pipes with a
• 2 traverses is the recommended configuration for pipes smaller than DN 600.
• 4 traverses can only be used for DN 50 in exceptional circumstances. The
CABLE LENGTH
Use this function to select the length of the sensor cable.
Options:
LENGTH 5 m/15 feet
LENGTH 10 m/30 feet
LENGTH 15 m/45 feet
LENGTH 30 m/90 feet
LENGTH 60 m/180 feet
LENGTH 100 m/300 feet
Factory setting:
LENGTH 5 m/15 feet
!
The influence on the flow measurement caused by the cable length is minimal with
nominal diameters under DN 80. For larger nominal diameters, the result is negligible.
Note!
wall thickness greater than 4 mm or if the signal strength is not sufficient in other
arrangements.
recommended configuration is 1 traverse.
Note!
Description of device functions
93