Operation
!
38
5.3.5
Device status/diagnosis messages
You can read the extended device status, in this case, current diagnosis messages, via
Command "48". The command delivers bit-encoded information (see table below).
Note!
• For detailed information on the device status/diagnosis messages and how they are rectified
→ ä 50
• Bits and bytes not listed are not assigned.
Byte
Bit
Diagnosis code
0
C - 284
1
C - 481
2
C - 281
3
C - 411
0
4
F - 001
5
F - 282
6
F - 283
7
F - 062
0
F - 062
1
F - 881
2
C - 431
3
C - 412
1
4
C - 413
5
C - 461
6
C - 453
7
C - 484
0
C - 485
1
C - 482
2
C - 482
3
C - 482
2
4
C - 482
5
S - 461
6
S - 461
7
S - 461
0
S - 437
1
S - 437
2
3
3
4
5
6
7
Brief description of the diagnosis message
Software update
Diagnosis active
Initialization
Upload/download
Device fault
Data storage
Memory contents
Sensor connection
Sensor connection
Sensor signal
Calibration
Writing backup
Reading backup
Signal output
Hide value
Simulation error
Simulation value
Simulation output
Simulation output
Simulation output
Simulation output
Signal output
Signal output
Signal output
Configuration
Configuration
-
-
-
-
-
-
-
-
-
-
-
-
Proline Prosonic Flow 91