Proline Prosonic Flow 91
Design, dimensions
Weight
Materials
Display elements
Operating elements
Remote operation
Languages
Endress+Hauser

10.1.10 Mechanical construction

The dimensions and lengths of the sensor and transmitter can be found in the "Technical
Information" document for the device in question. This can be downloaded as a PDF file from
www.endress.com. A list of the "Technical Information" documents available is provided in Section
"Documentation" on → ä 66.
• Transmitter housing: 2.4 kg (5.2 lb)
• Flowrate measuring sensors W (clamp-on) incl. mounting rail and tensioning bands:
2.8 kg (6.2 lb)
Transmitter
Wall-mounted housing: powder-coated die-cast aluminum
Sensor
Prosonic Flow W clamp-on version
• Sensor holder: stainless steel 1.4308/CF-8
• Sensor housing: stainless steel 1.4301/304
• Strapping bands/bracket: stainless steel 1.4301/304
• Sensor contact surfaces: chemically stable plastic
Connecting cable (sensor/transmitter)
• PVC connecting cable
– Cable sheath: PVC
– Cable connector: nickeled brass 2.0401/C38500

10.1.11 Human interface

• Liquid crystal display: illuminated, two lines with 16 characters per line
• Custom configurations for presenting different measured value and status variables
• 1 totalizer
Local operation via three operating keys (S, O, F)
Operation via HART protocol and FieldCare
English, German, Spanish, Italian, French