4. Once the A-VarioBell picks up the system is in programming mode.
In this mode it is possible to change the password 44xxxx;
5. Switch 'DIP 1' to 'OFF'; and
6. Close the front cover.
Parameter
Value
45
46
Dd
command to switch over to the DAY mode [2 spaces] /
Nn
command to switch over to the NIGHT mode [2 spaces] /
1
/
command is always 2 digits, but if you wish to switch over from Day to
Night with a single digit from the phone, there is an option to input "*a",
where a is a single number and the star represents an empty space and
must be in the first place
Note. The Day/Night mode stays even after line disconnection.
Parameter
Value
47
e – Choice of mode numbers; e=0 selects numbers from first and second
group, e=1 selects numbers in accordance with the Day/Night mode.
WARNING !! setting this parameter materially affects the number dialling!
Parameter
Value
49
o – o=0 dial a number like a phone (input the whole number)
o=1 input a 2 digit number (memory) on the keyboard, where the number
is saved into the memory (the memory number is the same as button
number and respects Day/Night switch over – numbers 01 - 99)
WARNING !! setting this parameter materially affects keyboard function!
Meaning
Command for switch over to DAY
dd
Command for switchover to NIGHT
nn
(e.g. parameters 35,36)
Meaning
Mode of door phone dial
e
(0/1)
Meaning
o
Regime keyboard
(00-99,*0-*9)
(0099,*0-*9)
A-VarioBell – User and service manual
Default
11
10
1
1
Default
1
Default
0
(0/1)
47