Single Slope Mode (Default Mode); Dual Slope Mode (1 Knee Point); Triple Slope Mode (2 Knee Points) - Automation Technology C2 Series User Manual

For high speed 3d sensors
Table of Contents

Advertisement

Single Slope Mode (Default Mode)

Weld Seam

Dual Slope Mode (1 Knee Point)

Weld Seam

Triple Slope Mode (2 Knee Points)

Weld Seam
C2 Series User Manual Rev. 1.9
Intensity
Saturation
1
1
100%
0%
Intensity
Knee Point 1
Saturation
100%
Saturation
Threshold 1
0%
Exposure
Limit 1
Intensity
Knee Point 1
Saturation
100%
Saturation
Threshold 2
Saturation
Threshold 1
0%
Exposure
Limit 1
2
2
3
3
Exposure Time
1
1
2
2
3
3
Exposure
Time
Knee Point 2
1
1
2
2
3
3
Exposure
Limit 2
Exposure
Time