SPC Series Solar Pump Inverter
6.2 Function parameters special for solar water pump
P11 group Protection
Function
code
decrease at
P11.01
sudden power
decrease ratio
P11.02
Current limit
P11.05
P11.06
current limit
decrease ratio
P11.07
Inverter/motor
P11.08
Name
Frequency
0: Disable
1: Enable
loss
0.00Hz–P00.03/s
If the bus voltage drops to the sudden
frequency decreasing point due to the
Frequency
power loss of the grid, the inverter begins
to decrease the
at sudden
according to
power loss
power generation state. The regenerative
power can maintain the bus voltage to
ensure normal running of the inverter
until the recovery of power.
0x00–0x12
Ones place: Current limit action selection
0: Invalid
1: Valid
2: Invalid during DEC
selection
Tens: Hardware current limit overload
alarm selection
0: Valid
1: Invalid
Automatic
50.0–200.0%
threshold
Frequency
0.00–50.00Hz/s
in current
limiting
0x0000–0x1131
OL/UL
Ones place:
pre-alarm
0: Motor OL/UL pre-alarm, relative to the
selection
motor rated current
Description
running
P11.02
to make the motor in
-35-
Function parameter list
Default Modify
0
frequency
10.00Hz/
s
0x01
120.0%
10.00Hz/
s
0x0000
○
○
◎
◎
◎
○