SPC Series Solar Pump Inverter
Function
code
Empty-water
P15.16
Empty-water
P15.17
level wake-up
Water pump
P15.19
underload state
detection value
P15.20
at underload
P15.21
Name
0–10000s
Time setting on empty-water level delay.
level delay
(This parameter is still valid for digital
empty-water signal.)
0–10000s
Time
wake-up delay. (This parameter is still
delay
valid for digital empty-water signal.)
0.0–1000.0s
Duration in which the water pump runs in
run time in
underload state. In continuous underload
condition, the underload alarm (A-LL) is
reported when the run time is reached.
0.0%: Automatic detection on underload
0.1–100.0%
The value 0.0% indicates it is determined
by the underload detection mechanism of
the inverter.
A value rather than 0.0% indicates it is
determined by P15.20. 100.0%
corresponds to the motor rated current.
Current
When the absolute value of target
frequency minus ramp frequency is less
than or equal to
running
threshold): If the actual current value at
the actual frequency is continuously less
than P15.20, the system reports the
underload fault with a delay specified by
P15.19. Otherwise, the system runs
properly. In the non-continuous situation,
the
cleared.
0.0–1000.0s
Underload reset delay.
Underload
In underload state, the counting on the
reset delay
underload run time and that on the
underload reset delay are performed
Description
setting
on
empty-water
P15.22
delay
counter
-43-
Function parameter list
level
(lag frequency
is
automatically
Default Modify
○
5s
○
20s
○
60.0s
○
00.00%
○
120.0s