Chapter 37 Access Control
Table 75 SNMPv2 Traps (continued)
TRAP NAME
thermalSensorFailure
adslAtucLof
adslAturLof
adslAtucLos
adslAturLos
adslAturLpr
adslAtucLofClear
adslAturLofClear
adslAtucLosClear
adslAturLosClear
adslAturLprClear
adslAtucPerfLofsThreshTrap
adslAtucPerfLossThreshTrap
adslAtucPerfLprsThreshTrap
adslAtucPerfESsThreshTrap
adslAtucPerfLolsThreshTrap
adslAturPerfLofsThreshTrap
adslAturPerfLossThreshTrap
adslAturPerfLprsThreshTrap
adslAturPerfESsThreshTrap
adslAtucSesLThreshTrap
244
DESCRIPTION
This trap is sent when the thermal sensor fails.
This trap is sent when a Loss Of Frame is detected on the ATUC.
This trap is sent when a Loss Of Frame is detected on the ATUR.
This trap is sent when a Loss Of Signal is detected on the ATUC.
This trap is sent when a Loss Of Signal is detected on the ATUR.
This trap is sent when a Loss Of Power is detected on the ATUR.
This trap is sent when the Loss Of Frame detected on the ATUC is
over.
This trap is sent when the Loss Of Frame detected on the ATUR is
over.
This trap is sent when the Loss Of Signal detected on the ATUC is
over.
This trap is sent when the Loss Of Signal detected on the ATUR is
over.
This trap is sent when the Loss Of Power detected on the ATUR is
over.
The number of times a Loss Of Frame has occurred within 15 minutes
for the ATUC has reached the threshold. currValue is the number of
times a Loss Of Frame has occurred within the 15-minute interval.
The number of times a Loss Of Signal has occurred within 15 minutes
for the ATUC has reached the threshold. currValue is the number of
times a Loss Of Signal has occurred within the 15 minute interval.
The number of times a Loss Of Power has occurred within 15 minutes
for the ATUC has reached the threshold. currValue is the number of
times a Loss Of Power has occurred within the 15-minute interval.
The number of error seconds within 15 minutes for the ATUC has
reached the threshold. currValue is the number of error seconds that
have occurred within the 15-minute interval.
The number of times a Loss Of Link has occurred within 15 minutes for
the ATUC has reached the threshold. currValue is the number of times
a Loss Of Link has occurred within the 15-minute interval.
The number of times a Loss Of Frame has occurred within 15 minutes
for the ATUR has reached the threshold. currValue is the number of
times a Loss Of Frame has occurred within the 15-minute interval.
The number of times a Loss Of Signal has occurred within 15 minutes
for the ATUR has reached the threshold. currValue is the number of
times a Loss Of Signal has occurred within the 15-minute interval.
The number of times a Loss Of Power has occurred within 15 minutes
for the ATUR has reached the threshold. currValue is the number of
times a Loss Of Power has occurred within the 15-minute interval.
The number of error seconds within 15 minutes for the ATUR has
reached the threshold. currValue is the number of error seconds that
have occurred within the 15-minute interval.
The number of severely errored seconds within 15 minutes for the
ATUC has reached the threshold. currValue is the number of severely
errored seconds that have occurred within the 15-minute interval.