18 Appendix; Fuses Type 5×20Mm - ABB CEMcaptain GAA610-M Operating Instruction

Advanced emission gas monitoring system for marine applications
Table of Contents

Advertisement

96
GAA610-M ADVANCED EMISSION GAS MONITORING SYSTEM | OI/GAA610-M-EN REV. B

18 Appendix

Fuses type 5×20mm
Marking
Function
-F70
Fuse protection 24V DC control emergency shutdown system (-K60, -S60)
-F71
Fuse protection 24V DC control of sample gas valve (-Y60)
-F72
Fuse protection 24V DC control of blowback valves (-Y61,-Y62)
-F73
Fuse protection 24V DC signal lamps (-H61,-H62,-H63,-H64)
-F74
Fuse protection 24V DC u-Remote CAN-Bridge (-D60)
-F75
Fuse protection 24V DC relay for signal doubling (-K61,-K62)
-F
SCC-F: Fuse protection 230V entire unit and cooler SCC-C
Tripping characteristic
Tripping current
time-lag fuse
2A
time-lag fuse
2A
time-lag fuse
2A
time-lag fuse
2A
time-lag fuse
2A
time-lag fuse
0,5A
time-lag fuse
6,3A