Measurement Ranges; Inputs And Outputs; Analog Output; Digital Output - ABB CEMcaptain GAA610-M Operating Instruction

Advanced emission gas monitoring system for marine applications
Table of Contents

Advertisement

10
GAA610-M ADVANCED EMISSION GAS MONITORING SYSTEM | OI/GAA610-M-EN REV. B
... 2 Design and function

Measurement ranges

Sample components and measuring ranges
Sample component
Standard measuring ranges
CO
0 to 20 Vol.-%
2
SO
0 to 250 ppm
2
0 to 500 ppm
SO
/CO
ratio
Calculated
2
2
O
(option)
0 to 25 Vol.-%
2
CO (option)
0 to 500 ppm

Inputs and outputs

Analog output

The measured concentrations of CO
SO
/CO
are available as 4 to 20 mA signals for further use in the
2
2
process control system.

Digital output

The following digital signals are provided for the process control
system of the ship:
System failure / common alarm
Maintenance
Maintenance Request
SO
meas. range feeback
2
Further digital signals can be added
and SO
as well as the ratio
2
2